Toyotomi TAN-A10SC User Manual page 22

Wall mounted air conditioner inverter type
Table of Contents

Advertisement

Available languages

Available languages

NOTICE
Take
sufficient
measures when installing the
outdoor unit.
Make sure the support can
withstand at least four times of
the unit weight.
The outdoor unit should be
installed at least 3cm above
the floor in order to install
drain joint. (for the model with
heating tube, the installation
height should be no less than
20cm.)
For the unit with cooling capacity of 2300W ~ 5000W, 6 expansion
screws are needed ; for the unit with cooling capacity of
6000W~8000W, 8 expansion screws are needed; for the unit with
cooling capacity of 10000W~16000W, 10 expansion screws are
needed.
Step 2:
Install drain joint (only for some
models)
1. Connect the outdoor drain joint
into the hole on the chassis, as
shown in the picture below.
2. Connect the drain hose into the
drain vent.
NOTICE
As for the shape of drainage joint, please refer to the current
product. Do not install the drainage joint in the severe cold area.
Otherwise,it will be frosted and then cause malfunction.
protective
22
at least 3cm above the floor
drain vent
Drain hose
outdoor drain joint
chassis
GB