CONNECTING INLET HOSES
(on some models)
To produce steam, the dryer must connect to the cold
water supply. Since the washer must also connect to the
cold water, a "Y" connector is inserted to allow both inlet
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never
use old hoses.
1. Turn the cold water faucet off. Remove the washer inlet
hose from the washer fill valve connector (cold).
2. Ensure the rubber flat washer is in place and screw the
female coupling of the short hose onto the washer fill
valve connector. Tighten by hand until firmly seated.
3. Attach the female end of the "Y" connector to the
male coupling of the short hose. Ensure the rubber flat
washer is in place. Tighten by hand until firmly seated.
B
cn
4. Insert the filter screen in the coupling of the washer's
inlet hose. If a rubber flat washer is already in place
remove it before installing the filter screen. Attach this
coupling to one male end of the "Y" connector. Tighten
by hand until firmly seated.
5. Ensure the rubber flat washer is in place and attach the
dryer's long inlet hose to the other male end of the "Y"
connector. Tighten by hand until firmly seated.
6. Ensure the rubber flat washer is in place and attach
the other end of the dryer's long inlet hose to the fill
valve connector at the bottom of the dryer back panel.
Tighten by hand until firmly seated.
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the couplings may
result.
8. Turn the water faucet on.
9. Check for leaks around the "Y" connector, faucet and
hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed within 42
in. (LO7 cm) of your washer's water inlet. The faucets
MUST be 3/4 in. (1.9 cm) garden hose-type so inlet hoses
can be connected. Water pressure MUST be between 10
and 120 pounds per square inch. Your water department
can advise you of your water pressure.
NOTE: A water softener is recommended to reduce
buildup of scale inside the steam generator if the home
water supply is very hard.
SERVICING
A WARNING - LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.
For servicing phone numbers for replacement parts, and
other information, refer to Owner's Manual or visit our
Web site.
REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY
IMPORTANT PRODUCT NOTIFICATIONS.
Please go to www.GEAppliances.com or mail in your
Product Registration Card.
For questions on installation, call: 800.626.2000 (US) or
800-561-3344 (Canadal.

Advertisement

loading

This manual is also suitable for:

Ghdn520ed1wsGtds570ed1wwGtdp450ed0wsDhdsr46eg8ww