NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in
an "electrolysis" effect occurring in the fountain. This may result in water which has a metallic taste to it or
has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate the
fountain from the remainder of the building's plumbing circuits.
ENOB2-8C, ENOB2-8RAC
INSTALLATION & USE MANUAL
Refrigerated fountains with FLEXI-GUARD
ENOB2-8C
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left with building owner
for future reference.
Service to be performed by authorized service personnel only.
WWW.RESTROOMDIRECT.COM
ENOB2-8RAC
Page 1
704 • 937• 2673
98005C (REV. E - 10/18)
129 Oakpark Dr., Unit A, Mooresville, NC 28115
®

Advertisement

Table of Contents
loading

Summary of Contents for Elkay SWIRLFLO ENOB2-8RAC

  • Page 1 ENOB2-8C, ENOB2-8RAC INSTALLATION & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD ® ® ENOB2-8C ENOB2-8RAC INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. When installation is complete, ensure these instructions are left with building owner for future reference.
  • Page 2 ENOB2-8C, ENOB2-8RAC Page 2 98005C (REV. E - 10/18) WWW.RESTROOMDIRECT.COM 704 • 937• 2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115...
  • Page 3: Required Tools And Materials

    ENOB2-8C, ENOB2-8RAC REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE Additional Materials Item Description Quantity Unplated copper inlet pipe Service Stop 1.
  • Page 4 ENOB2-8C, ENOB2-8RAC Attach waste tube (1-1/4” O.D.) to 1-1/4” O.D. slip trap (provided by others). Connect the fountain drain waste tube to the building 24, 25 sanitary sewer system. Connection should be made in compliance with local plumbing code requirements. (Note: Plumbing trap is not included with the fountain).
  • Page 5 ENOB2-8C, ENOB2-8RAC ENOB2-8C ENOB2-8RAC Figure 7 - Solenoid Assembly CONNECT TO FOUNTAIN SEN- SOR WIRING CONNECTOR REGULATOR Figure 8 - Regulator Assembly (Item 7) Page 5 98005C (REV. E - 10/18) WWW.RESTROOMDIRECT.COM 704 • 937• 2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115...
  • Page 6 ENOB2-8C, ENOB2-8RAC See Fig. 10 Figure 9 - Exploded View BASIN Locknut NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. Figure 10 - Bubbler Assembly Page 6 98005C (REV. E - 10/18) WWW.RESTROOMDIRECT.COM 704 •...
  • Page 7 ENOB2-8C, ENOB2-8RAC See Fig. 10 See Fig. 10 Figure 11 - Fountain Body Assembly REGULATOR Figure 12 - Push Button Assembly Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.
  • Page 8: Parts List

    FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com Page 8 98005C (REV. E - 10/18) WWW.RESTROOMDIRECT.COM...

This manual is also suitable for:

Swirlflo enob2-8cSwirlflo enobm8k

Table of Contents