25 w tamamen kendi sorumluluǧunda olmak üzere bu bildirinin ilgili olduǧu klima modellerinin aşaǧıdaki gibi olduǧunu beyan eder: FTXM20M2V1B, FTXM25M2V1B, FTXM35M2V1B, FTXM42M2V1B, CTXM15M2V1B, ATXM20M2V1B, ATXM25M2V1B, ATXM35M2V1B, 01 are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our 08 estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de...
Page 3
18 ** DICz*** este autorizat să compileze Dosarul tehnic de construcţie. 24 ** Spoločnosť DICz*** je oprávnená vytvoriť súbor technickej konštrukcie. 25 ** DICz*** Teknik Yapı Dosyasını derlemeye yetkilidir. ***DICz = Daikin Industries Czech Republic s.r.o. Tetsuya Baba Managing Director...
Safety Precautions Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. •...
CAUTION • Do not install the air conditioner at any place where there is a danger of flammable gas leakage. In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. •...
Preparation before Installation Removing and installing front panel • Removal method 1) Place your fingers in the indentations on the main unit (one each on the left and right sides), and open the front panel until it stops. 2) Continue to open the front panel further while sliding the panel to the right and pulling it toward you in order to disengage the front panel Rotating shaft shaft on the left side.
Class 50/60/71: Titanium apatite photocatalytic air-purifying filter Streamer Remote controller holder ew for remote controller holder : M3 × 20L) WARNING • Use only Daikin optional parts approved for this model. English...
Indoor Unit Installation Installing the mounting plate • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
Page 9
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole gap with putty. English...
Indoor Unit Installation Installing the indoor unit • In the case of 1) Cut off the pipe port bending or curing cover from inside refrigerant pipes, the front grille using keep the following a copping saw. precautions in Apply the blade of mind.
Page 11
Indoor Unit Installation 3-2. Left-side, left-back, or left-bottom piping How to replace the drain plug and drain hose • Replacing onto the left side Drain hose attachment position 1) Remove the insulation fixing screw on the * The drain hose is on the back of the unit. right and remove the drain hose.
Indoor Unit Installation Wiring diagram For applied parts and numbering refer to the wiring diagram sticker supplied on the unit. Part numbering is realized by Arabic numbers in ascending order for each part and is represented in the overview below by symbol “*” in the part code. CONNECTION PROTECTIVE EARTH (SCREW) CONNECTOR...
Indoor Unit Installation Wiring 1) Strip wire ends (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals. 3) Connect the earth wires to the corresponding terminals. 4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
Page 14
Indoor Unit Installation Wireless adapter (option) Preparation of wire for WLAN adaptor connection Class 15/20/25/35/42 Class 50/60/71 Remove tape Cut the clip Remove the connector from protective sleeve • For connection of wire with WLAN adapter - see WLAN option kit Installation manual. Class 15, 20, 25, 35, 42 Installing: •...
Refrigerant Piping Work Flaring the pipe end (Cut exactly at 1) Cut the pipe end with a pipe cutter. right angles.) Remove burrs. 2) Remove burrs with the cut surface facing Flaring downward so that the chips do not enter the pipe. Set exactly at the position shown below.
Refrigerant Piping Work 2-2. Selection of copper and heat insulation materials Inter-unit wire • When using commercial copper pipes and fittings, observe the following: Gas pipe 1) Insulation material: Polyethylene foam Liquid pipe Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mh°C) Refrigerant gas pipe’s surface temperature reaches 110°C max.