Electrical connection
Local and national electrical regulations must be observed.
All instructions given by the Electricity Board must be followed carefully when connecting
the oven to the mains supply.
This is a job for a qualified and approved electrician. The appliance is rated for 240 volts sin-
gle phase and must be permanently connected.
The cooker must be installed in such a way that it can be easily disconnected from the mains
supply before servicing, e.g., by an adjacent cooker control unit.
Sufficient cable should be left to enable the appliance to be removed from the housing unit
whilst still connected to the mains supply.
WARNING - THIS APPLIANCE MUST BE EARTHED!
Voltage an current
Please ensure that the volltage and current indicated on the rating plate agrees with the vol-
tage of your electricity supply 220-240 volts i.e., 220-240 V a.c.
1. Open the cover of the terminal box sideways as illustrated in fig. G
2. Pass cable through the grommet in the lower back panel and the cable clamp.
3. Connect the wires to the terminals in accordance with the diagram. Ensure that links are
correctly positioned between terminals (5 or 6 way terminal block). The length of the
earth conductor must be adequate to ensure that in case of the cable clamp breaking
the earth wire is subject to mechanic strain only after the live wires.