6.0 RESTORING THE DRIVE CONFIGURATION
After the Regulator board has been replaced, the drive powers up with the parameterssetto their
factory-default values. If you changed any of the parameters from their default values prior to
replacing the board, you must change them again after you have completed the Power Module
identification procedure described in Chapter5.
Use one of the following procedures to restore your configuration:
e lf you have purchased the Configuration Executive 3000 (CE3000) software and saved your
configuration to your personal computer prior to replacing the Regulator board, you can use the
CE3000 software to load the configuration to the new Regulator board. Refer to the CE3000
instruction manual (D2-3303) for this procedure.
e@ Ifyou are using the keypad to configure the drive and you have a record of the changes made to
the parameter settings, you will need to change only those parameters affected. Refer to
instruction manual D2-3323 for parameter descriptions.
e@ lf you are using the keypad to configure the drive and you have no record of changes made to the
parameters, you will need to perform the appropriate start-up procedurein instruction manual
D2-3323.
6-1