IMPORTANT INSTRUCTIONS -
Models: AIK14XL, AIK26YL, AIG46HL,
AIG46F, AIK14XF, AIK26YF
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
WARNING:
DO NOT CONNECT POWER SUPPLY UNTIL FAN
IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
TO THE FAN IS LOCKED IN OFF POSITION.
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
5S7635037 New 10-06
OPERATING MANUAL

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
9. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
10. Suitable for use with solid-state speed control.
11. This unit has rotating parts and safety precautions should be
exercised during installation, operation and maintenance.
12. Guards must be installed when fan is within reach of personnel
or within seven (7) feet of working level or when deemed
advisable for safety.
13. NEVER place a switch where it can be reached from a tub or
shower.
14. Do not insert or allow fingers or foreign objects to enter the
motor.
WARNING:
www.airkinglimited.com
In-Line Exhaust Fan
with Light
DO NOT USE IN KITCHENS
1 of 16

Advertisement

Table of Contents
loading

Summary of Contents for Air King In-Line Exhaust Fan AIG46F

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AIK14XL, AIK26YL, AIG46HL, AIG46F, AIK14XF, AIK26YF READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Vertical Mounting

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing for Fan Installation 1. When selecting fan mounting location, the following criteria should be considered: a) Mounting to minimize noise generated by fan operation: Mounting the fan as far as possible from the intake point will minimize fan operating noise from being transmitted back through the duct work.
  • Page 3 Housing Locating Tabs Mounting Rails Figure 4 NOTE: If drywall or ceiling material will be thicker than 5/8" the height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material.
  • Page 4 Ceiling Housing Grill Collar Figure 10 SECTION 6 Ducting CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. NOTE: Insulated ducting is required for bathroom exhaust applications, where ducting passes through unconditioned space or where noise is a factor. Failure to use insulation could result in excessive condensation buildup within the duct, and undesirable sound levels within the room.
  • Page 5 CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 1. Remove the screws securing the terminal box cover plate located on the side of the motor (Figure 13).
  • Page 6: Troubleshooting Guide

    Halogen Models: Remove the lamp, by gently rotating until it releases from the socket and replace with Air King model 50WHA or an equivelent 50 watt, MR16, 120 volt EXN/GU10 lamp (Figure 17) .
  • Page 7: Limited Warranty

    Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 8: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Halogen Lamp Fan Kit Replacement Parts Qty. Description Motor - AIK14XL Motor - AIK26YL Cover Plate - AIK14XL Cover Plate - AIK26YL Screw Screw Mounting Bracket Grommet Screw Y Transition - AIK26YL Screw Mounting Rail Grill Housing Light Socket Assembly Screw Grill...
  • Page 9 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: AIK14XL, AIK26YL, AIG46HL, AIG46F, AIK14XF, AIK26YF LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 10 INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation en prévision de l’installation du ventilateur 1. Lorsque vous choisissez l’emplacement pour l’installation du ventilateur, les critères suivants doivent être pris en compte : a) Installation visant à...
  • Page 11 Châssis Onglets de localisation Traverses de montage Figure 4 REMARQUE : Si l’épaisseur de la paroi sèche ou du matériel du plafond est de plus de 15,88 mm, la hauteur du châssis devra être ajustée pour compenser et les onglets de repère pliés à égalité du châssis de sorte que le collet de la grille soit à...
  • Page 12 REMARQUE : Si l’épaisseur de la paroi sèche ou du matériel du plafond est de plus de 15,88 mm, la hauteur du châssis devra être ajustée pour compenser et les onglets de repère pliés à égalité du châssis de sorte que le collet de la grille soit à effleurement du matériel de plafond final.
  • Page 13 3. Insérez l’arbre du clapet dans le trou perforé à l’étape 2. Placez la rondelle, la poignée et ensuite l’écrou à oreille dans l’arbre (Figure 12). Ecrou à oreille Rondelle Trou Embranchement en “ Y ” Figure 12 4. Ajustez le clapet de sorte à équilibrer le débit d’air et serrez l’écrou à...
  • Page 14: Guide De Dépannage

    Modèles à halogène : Retirez la lampe en la faisant doucement tourner jusqu’à ce qu’elle se libère de la douille et remplacez- la avec une lampe Air King modèle 50WHA ou équivalent de 50 watts, MR16, 120 volts EXN/GU10. Lampe Modèles à...
  • Page 15: Garantie Limitée

    Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 16 DIAGRAMME DES PIÈCES DE REMPLACEMENT Pièces de remplacement pour ensemble de ventilateur à lumière à halogène Qté. Description Moteur - AIK14XL Moteur - AIK26YL Plaque de finition - AIK14XL Plaque de finition - AIK26YL Support de montage Passe-câble Embranchement en “ Y ” - AIK26YL Traverses de Montage Châssis de la grille Assemblage du socle de lumière...