Indoor Fan Bearing - Haier GE AZ45E07EACW5 Technical Service Manual

2019 zoneline air conditioner
Table of Contents

Advertisement

Indoor Fan Bearing

Remove six screws to remove the end cap to
access the bearing assembly. Two screws are
used to secure the bracket attached to the indoor
coil and end cap.
Components: Indoor Fan Bearing
Proper Bearing Placement
NOTE: When reinstalling the bearing, ensure
the shaft goes directly into the bearing assembly.
The image above shows proper placement of the
bearing. Failure to install properly will result in a
noise complaint.
– 41 –

Advertisement

Table of Contents
loading

Table of Contents