Fan Cycle: Resistance Heating Mode - Haier GE AZ45E07DABW5 Technical Service Manual

2019 zoneline air conditioner
Hide thumbs Also See for GE AZ45E07DABW5:
Table of Contents

Advertisement

Fan Cycle - Resistance Heating Mode
The indoor fan and heaters are turned ON at the same time. The indoor fan is turned OFF,
approximately 20 seconds after the heaters are de-energized as shown. In the OFF mode, the indoor
fan will continue to operate for 6 seconds after the user has stopped the Zoneline, in order to dissipate
the heat inside the Zoneline.
In the heating mode, the indoor fan is designed to operate at two different speeds (RPM).

FAN CYCLE: RESISTANCE HEATING MODE

Temperature
Temperature Setting
-1.8°F
Heater
INDOOR FAN
ON
20 sec
– 14 –
ON
ON