Summary of Contents for Webasto BlueCool V-PRO Series
Page 1
Operating Instructions Marine Chiller Air-Conditioning Systems BlueCool V-PRO English This document is valid for: V-PRO60 M -400V -REV -R410a 2510228A V-PRO90 M -400V -REV -R410a 2510229A V-PRO130 M -400V -REV -R410a 2510230A V-PRO180 M -400V -REV -R410a 2510231A...
Purpose of this document.......... 3 Using this document.......... 3 Use of symbols and highlighting ........ 3 Warranty and liability.......... 3 Webasto Service App.......... 3 Safety .......... 3 Intended use ............. 3 Regulations and legal requirements ...... 3 Unit details ......... 3 Conformity ..............
Purpose of this document Intended use The Operating Instructions (OI) are an integral part of the The BlueCool V-PRO Series is used for heating and cooling on product and provide the information required to ensure correct boats and ships. and safe operation.
NOTE 4.2.4 Operation Webasto recommends operating the screen using your fingers only. The touch sensitivity of the screen is op- After switching on, the control system starts up all V-PRO units timized to fingertip contact. The screen may not re- within the system in steps in the selected operating mode.
Page 5
Operation | 4 4.2.5 Select operating mode The Operating Mode button (6) is used to set the operating mode. The options are: l COOL (cooling mode) l HEAT (heating mode) l HEAT AUX (Heating mode combined with an external heater) NOTE If a different operating mode is selected when the unit is in operation, then the whole system initially shuts...
The sea water circuit must only be cleaned by an expert (in- – The selected settings are then adopted. staller or Webasto Service Centre). Tap the Home screen (symbol: ) symbol to return to the Cold water circuit Home screen.
Decommissioning | 6 l In closed systems, check the static prepressure in the sys- tem at least once a month. In the event of a pressure drop, repair leaks and top up with water/glycol mixture. l Check the entire cold water circuit for leaks at least once a month;...
Correction E100 - Undervoltage Switch-off in case of undervoltage. Power supply Please contact your authorised Webasto Marine dealer. below set undervoltage value for longer than 5 seconds. Cause is probably excessively long cable, overloading or an insufficiently high power gen- erator output.
Page 9
Status / Error message Possible cause Correction E201 - Cold water temperature Cold water temperature sensor defective or Please contact your authorised Webasto Marine dealer. sensor outlet break/short-circuit in electrical circuit. 10 E202 - Cold water temperature Cold water temperature sensor defective or Please contact your authorised Webasto Marine dealer.
35 E353 - Power supply is not normal The power supply is faulty. Check on-shore connection or generator. 36 E361 - Compressor speed Incorrect speed or incorrect parameters at too Please contact your authorised Webasto Marine dealer. high a load. 37 E362 - Compressor overload Maximum permissible current was exceeded Please contact your authorised Webasto Marine dealer.
Page 11
Slovenščina Colour Background colour White White Black Standby Selects the standby mode display 1 Webasto logo Webasto logo 2 Customer logo 3 Standby off °C, °F 4 System: cold water temperature °C, °F 5 System: sea water temperature A; % 6.
Page 12
To request this documentation in another language, please locate and contact your local Webasto dealer. You can find your nearest dealer at: https://dealerlocator.webasto.com/en-int. To provide feedback (in English or German), please email: feedback2tdt@webasto.com Europe, Asia Pacific: UK only: USA only: Webasto Thermo &...
Need help?
Do you have a question about the BlueCool V-PRO Series and is the answer not in the manual?
Questions and answers