4.
Turn the ignition power to the ON position, but do not start the car.
5.
Turn the Master Enable switch to the ON position. The red LED should be on now.
6.
Connect the hand held programmer to the USB cable and program the unit to the recommended base settings shown in section
2.8.1. Additional instructions are included with the 2-stage mini progressive controller for creating custom settings.
7.
Once programming is complete, turn the ignition switch off for 10 seconds, then back to the ON positon; do not start the engine
yet.
8.
Verify the programmer display shows an
controller instructions for more information.
9.
You are now ready to drive the car and test the operation of the nitrous system.
WARNING! It is VERY important to use caution and good safety practices when testing and using any nitrous oxide system.
We do not recommend the use of nitrous on any public streets or highways. It is recommended to only test and
use nitrous in a controlled, closed course location, such as a race track.
WARNING! Never activate nitrous with the vehicle in "NEUTRAL" or "PARK"!
WARNING! Never activate nitrous at engine speeds below 3000 RPM, or engine damage may result!
WARNING! SEVERE ENGINE DAMAGE MAY OCCUR IF NITROUS IS ACTIVATED WHILE TRACTION CONTROL DEVICES ARE
ENABLED. TRACTION CONTROL DE-ACTIVATION MUST BE CYCLED EVERY TIME THE IGNITION SWITCH IS
CYCLED.

2.8.1 Programming the Mini 2-Stage Progressive Controller

The following settings are a good baseline from which to start. Additional or Custom settings can be programed by following the User
Guide suppled with the Mini 2-Stage controller.
Switch #1 - toggles through the configuration menu. As you toggle through the configuration menu, the stored value will be displayed.
Use this switch to toggle to the next step in programming mode (Press switch #1, 2 times).
Switch #2 - increments the flashing value that was selected by switch #1.
LED A.B.C - displays the configuration step number and its setting
A = this is the step being programmed
B & C = value for the current configuration step
To enter the programming mode:
Press and hold both switches until "Pro" is displayed. Now release the switches and the unit will automatically go to the first
configuration step.
STEP F. SOLENOID FREQUENCY (Hz) = 20
STEP C. RPM SIGNAL SET-UP = 00
STEP P. RAMP PAUSE MODE = 00
1. ACTIVATION RPM = 40 (4000rpm)
NOTE: This setting can range from a minimum of any RPM greater than 0 rpm (3000 rpm recommended) up to a
maximum of 9900 rpm.
2. DEACTIVATION RPM = 65 (6500rpm)
NOTE: This setting should be set to 200 RPM below engine rev limiter (maximum of 9900 rpm).
3. DELAY TIME = 00 (zero seconds)
"r r".
If display show any other values than
A B C
Display reads; F.20
Display reads; C.00
Display reads; P.00
Display reads; 1.40
Display reads; 2.65
Display reads; 3.0.0
"r r"
, refer to page 2 of the Mini 2-Stage
Switch #1
Switch #2
13