Attach the screen brackets to the back of the screen using the corresponding toothed lock washers. The gap
between the rails and the top and bottom of the screen should be the same.
Use the corresponding hole in the multiwasher that matches your screw size.
If the screen has a curved back you may have to place the supplied spacers between the two screen
brackets and the screen. Make sure that the screen brackets do not press against the tvs rear panel.
Always tighten the screws by hand first to ensure that they are the correct thread size. Using incorrect
screws can cause permanent damage to the tv.
Make absolutely sure that the screws grip along their entire length into the threaded drill-holes of the screen
and that they are screwed tight. At the same time, you must also make sure that the screw threads do not
protrude too far into the inside of the screen, as this could damage sensitive parts.
If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not
tightly secured, damage may occur to screen or product may fail.
Attaching the screen to the wall plate
For heavy tvs, the installation must be carried out by two persons or with mechanical lifting equipment!
Align the two screen brackets (both must be set to the same position) and tighten the knobs so that nothing
can be displaced while the screen is being hooked on to the wall plate.
Hook the screen on to the wall plate from above. Then fasten the lock plate as shown in fig. 3b.
Now loosen the fixing knobs and adjust the screen angle as required.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
Observe prescribed testing deadlines:
1.
Once a year by an expert
2.
Every four years by a skilled person
3.
Before every use for breakage and function by the operator
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Carrying capacity:
75 kg (UL-certified)
Interface dimensios:
480 x 348 mm
Distance to wall:
75 mm
Dimensions:
528 x 348 x 75 mm
Weight:
6.2 kg
Max. service life:
10 years