GENERATOR
*Three-phase power Stand-by
**Three-phase power PRP
**Single-phase power PRP
Frequency
Cos ϕ
*
Output powers according to ISO 8528-1
ALTERNATOR
Type
Insulation class
ENGINE
Make / Model
Type / Cooling system
Cylinder / Displacement
*Stand by power
*PRP power
Speed
Fuel consumption (75% of PRP)
Engine oil capacity
Starter
Powers according to SAE J1349
*
GENERAL SPECIFICATIONS
Tank capacity
Running time (75% of PRP)
Protection
*Dimensions / max. on base Lxwxh (mm)
*Weight (dry)
**Acoustic power LwA (pressure LpA)
* Dimensions and weight are inclusive of all parts. **For fixed installation only in the EU market.
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (L
A) - Measure Unit dB(A):
W
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A):
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
A) of 95 dB(A)
(L
W
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE:
the symbol
according to 2000/14/CE directive.
GE 13054 HBS
13 kVA (10.4 kW) / 400 V / 18.7 A
11.5 kVA (9.2 kW) / 400 V / 16.6 A
6 kVA / 230 V / 26 A
50 Hz
0.8
self-excited, self-regulated
three-phase, synchronous
H
HONDA GX 630 (STAGE V)
Diesel 4-Stokes / air
2 / 688 cm
3
14.5 kW (19.7 HP)
10.5 kW (14.3 HP)
3000 rpm
3.9 l/h
1.9 l
Electric
18 l
4.5 h
IP 23
935x525x645
142 Kg
99 dB(A) (74 dB(A) @ 7 m)
OUTPUT
ACOUSTIC POWER LEVEL
it stands for acoustic noise released in a certain delay of time. This is not
it measures the pressure originated by sound waves emission. Its value changes
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)

TECHNICAL DATA

M
1.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc7m80139003

Table of Contents