Table of Contents

Advertisement

Quick Links

USER
MANUAL
No Climb Products Ltd.
163 Dixons Hill Road, Welham
Green. Hertfordshire, AL9 7JE,
United Kingdom
Tel +44 (0)1707 282 760
EU: shift-consult Hubert Scherzinger
Hessenweier 9,79108 Freiburg, DE
Tel: +49 (0) 7665 91 21 74
detectortesters.com
1
Testifire XTR2

Advertisement

Table of Contents
loading

Summary of Contents for Testifire XTR2

  • Page 1 USER MANUAL No Climb Products Ltd. 163 Dixons Hill Road, Welham Green. Hertfordshire, AL9 7JE, United Kingdom Tel +44 (0)1707 282 760 EU: shift-consult Hubert Scherzinger Hessenweier 9,79108 Freiburg, DE Tel: +49 (0) 7665 91 21 74 detectortesters.com Testifire XTR2...
  • Page 2: Cautions And Warnings

    • Do not leave a battery on prolonged charge when Avoid prolonged, direct exposure to the vapour not in use. generated by Testifire XTR2. Safety Data Sheets for • Do not use any battery which is not designed for the Testifire XTR2 battery pack and Testifire XTR2 use with this equipment.
  • Page 3: Kit Contents - What's In The Box

    ◦ Restrictions detailed in the Technical Information (see Section 12). • Testifire XTR2 may be used in ceiling and floor voids but care must be taken to ensure that the unit and cup can pass through gaps in both directions.
  • Page 4: Table Of Contents

    Removing the Battery for Charging Replacing the Battery Removing and Replacing the Membrane Detectortesters Cloud Portal Registering a New Account Verifying Your New Account Registering and Purchasing a Subscription for Testifire XTR2 8.3.1 Registering Testifire XTR2 8.3.2 Purchasing a Subscription for Testifire XTR2 8.3.3...
  • Page 5 9.8.6 Push Notifications 9.8.7 Vibration/Sound 9.8.8 Help 9.8.9 Give Feedback 9.8.10 Terms & Conditions 9.8.11 Privacy Policy 9.8.12 Deactivate Account 10. Consumables and Accessories 11. Troubleshooting 11.1 Device Error Codes 12. Support & Technical 12.1 Maintenance 12.2 Technical Information 12.3 Support Contact Testifire XTR2...
  • Page 6: General Instructions

    Goods supplied under these terms and conditions will be in accordance with the specification (if any) contained in the If the Testifire XTR2 is used in a manner not specified Purchase Order, and will be free from defects in workmanship...
  • Page 7: Testifire Xtr2 Introduction

    Thank you for purchasing the Testifire XTR2 multifunction Smoke-Heat Detector Tester. This manual is designed to assist you to get the best and most efficient use of the Testifire XTR2 and provides all the information required to perform routine service and maintenance tasks with ease. Testifire XTR2 includes advanced technology that simplifies functional testing of smoke, heat and multi-function detectors in the field.
  • Page 8: Preparation For First Use

    Sign into the Cloud Portal to register your device. You will need to purchase a subscription to use connected services however your XTR2 comes with an extended free trial which starts from the moment you register your device. You will be informed via the portal and DT Connect app Get the DT Connect app when your free trial subscription is about to expire.
  • Page 9: Charging The Battery

    • When replacing a generator, any dust or debris within • Do not charge the battery outside of the specified the Testifire XTR2 housing can be removed using an air operating temperature range (5-45°C). duster. Any condensation can be removed by wiping •...
  • Page 10: Inserting The Smoke Cartridge

    WARNING Figure 4 Do not touch the contacts on the PCB on the cartridge. Static electricity may cause damage and contamination of the contacts must be avoided. Figure 3 Testifire XTR2...
  • Page 11: Using Testifire Xtr2

    USING TESTIFIRE XTR2 4.1 Attaching Testifire XTR2 to Solo Access Poles Testifire XTR2 is designed for use with the Solo range of access poles (purchased separately). The product is not compatible with alternative poles. WARNING When working at height it is recommended that a Take the Solo access pole and press down the locking button on competent person carries out a suitable risk Testifire XTR2.
  • Page 12: Led Indicator Reference Chart

    The detector should touch the base of the Testifire XTR2 clear standoff and should be level with the base of the detector (Fig. 7) Adjust the head unit for the correct angle to access the detector.
  • Page 13: Performing A Test

    When the detector is activated, the preparation procedures your Testifire cup controls the test. optical LED reader inside the tester XTR2 will be ready for use. cup will sense the detector activation The test will begin automatically LED and automatically end the test.
  • Page 14: Heat Test

    The status LED will flash triple red to indicate the test has been unsuccessful Avoid placing hands near the and you should remove Testifire XTR2 duct outlet during heat testing or by gently lowering it. within 5 minutes of conducting heat testing.
  • Page 15: Combined Test

    (see section 5.5). Select the Combined function using To end clearing, remove Testifire the navigation arrows on the LCD XTR2 by gently lowering it (Fig. 16). Figure 15 display. Once selected the status LED’s will alternate between solid blue Figure 16 and solid red (Fig.
  • Page 16: Sequential Test

    5.4 Sequential Test Using Testifire XTR2 to carry out a The test will begin automatically Once the Sequential test is complete, sequential test means that a when the tester cup is placed over the the status LED’s will flash triple number of operations (Smoke, Heat detector, breaking the infrared beam.
  • Page 17: Clearing A Detector

    1. Open the DT Connect app on your mobile device 2. Pair your Testifire XTR2 device and start a new test job To perform clearing on its own, download the DT Connect app 3. Select your test location and tap “next step”...
  • Page 18: Manual Purge

    The device settings can be viewed by pressing the cog icon on used for a period of time, when in cold conditions, a new your Testifire XTR2 display (Fig. 23). From this menu you can generator has been installed or in the case of a significant view the following settings: drop in performance.
  • Page 19: Asd Adaptor - Testing Asd Systems And Flat Detectors

    Users should note that using Testifire XTR2 in this configura- the timer the status LED’s will flash orange tion is outside the scope of UL classification for Testifire XTR2. Locate Testifire XTR2 over the sampling hole. Smoke The application has been thoroughly tested independently with will automatically be generated for 20 seconds indicat- all ASD technologies and a wide range of Flat Detectors.
  • Page 20: Removing And Replacing Consumables

    REMOVING AND REPLACING CONSUMABLES All consumable parts of Testifire XTR2 can be replaced in the NOTE: field without having to return the unit for service. Do not re-use empty cartridges. Empty cartridges may be returned to the manufacturer via the reseller for...
  • Page 21: Replacing The Smoke Generator

    Figure 31 car adaptor (see Section 3.1) CHARGE CRADLE STATUS LED COLOUR FLASHING GREEN BATTERY CHARGING SOLID GREEN BATTERY FULLY CHARGED SOLID RED NO BATTERY CONNECTED FLASHING RED BATTERY FAULT Testifire XTR2...
  • Page 22: Detectortesters Cloud Portal

    Once you have completed the registration process you will need to verify your account. A verification email will be sent to the email address provided during the registration process (Fig. 35). Click the link to confirm your account before signing into the cloud portal Figure 35 Testifire XTR2...
  • Page 23: Registering And Purchasing A Subscription For Testifire Xtr2

    8.3 Managing Devices and Subscriptions 8.3.2 Purchasing a Subscription for Testifire XTR2 The Devices Dashboard provides a summary of all testers Once your register your new Testifire XTR2 you may purchase registered to your company, including: an optional subscription to enable premium features in the DT Connect app and Cloud Portal. To purchase a subscription, click •...
  • Page 24: Cancelling A Subscription

    Technicians need to be registered in order to use a company’s “Manage Subscriptions” and follow the instructions to Testifire XTR2. To add a technician go to “Technicians Tab” and cancel your plan (Fig. 40) click on “Add New User” (Fig 42.1) Figure 40 Figure 42.1...
  • Page 25: Settings Menu

    • Company details • Profile details • User password 8.6.1 Uploading a Company Logo To upload a company logo, click “Upload Logo”. Select your logo from the browser and click “Open (Fig. 44). NOTE: To remove a company logo, click the delete Figure 44 Testifire XTR2...
  • Page 26: Profile Details

    The “Profile Details” section can be used to edit company To change your password, click “Change Password”. Enter your profile information, including email address and Country. current password followed by your new password, then click (Fig. 46). “Save Changes”. (Fig. 47). Figure 46 Figure 47 Testifire XTR2...
  • Page 27: Dt Connect App

    Figure 49 The DT Connect app provides a number of features and benefits to help you make the most of your Testifire XTR2. This includes access to advanced test modes and digital test reports that provide proof of compliance. 9.1 Downloading the App The DT Connect app can be downloaded from the App Store for iPhone and the Google Play Store for Android devices.
  • Page 28 Figure 51 NOTE: A company ID is required to register a new profile in the DT Connect app. If you do not have this, ask your adminis- trator to register your account in the Cloud Portal (Section 8.5) Testifire XTR2...
  • Page 29: Pairing Your Testifire Xtr2

    Select your Testifire XTR2 device from the device list and tap “Confirm” Enter the Bluetooth passcode displayed on your Testifire XTR2 display Once your Testifire XTR2 is connected its serial number and consumables status are shown on the app home screen. Figure 52...
  • Page 30: Creating A New Test Job

    If you cannot find your location, tap “Can’t See Location?” and enter the address details manually (Fig. 53). Figure 53 Figure 54 NOTE: The test mode can be changed at any time after starting a test job Testifire XTR2...
  • Page 31: Performing A Test

    9.5 Performing a Test An infrared beam across the tester cup controls the test. The If after two minutes the test has not completed, Testifire XTR2 test will begin automatically when the tester cup is placed over will time-out and the test will be recorded as failed. The app will the detector, breaking the infrared beam.
  • Page 32: Aborted Tests

    An active test can be aborted before it is completed by removing When choosing the “Override Result” option, you will be the detector and gently lowering Testifire XTR2. The app will prompted to manually select if the test has passed or failed and indicate the test was aborted and a prompt will appear with you will need to add notes against the test record.
  • Page 33: Changing Test Mode

    To change test mode, tap “Change Test” and select a new test mode from the list (Fig. 60). When a new mode is selected the status LED’s on Testifire XTR2 will change to indicate the selected mode (see section 4.3)
  • Page 34: Changing Alarm Signal Mode

    LED. The LED detection mode needs to be in the appropriate the detector – clearing any lingering smoke via the vent in mode. In case Testifire XTR2 is not picking up the LED, the most the cup. likely resolution is to switch the detection mode.
  • Page 35: Using The Delayed Start Mode

    9.5.5 Using the Delayed Start mode ASD systems and Flat Detectors can be tested using the ASD Adaptor (Product Code: TESTIFIRE-ADAP-001). See section 6.2 for guidance on fitting the adaptor to the Testifire XTR2 test cup. Change the test mode to ASD once the ASD adaptor is installed and select a delay duration of either 5, 20 or 40 seconds (Fig. 63)
  • Page 36 Tap “start” when you are ready to begin the timer and begin positioning Testifire XTR2 (Fig. 64) Figure 64 Testifire XTR2...
  • Page 37: Closing A Test Job

    “Finish Test”. add any final test notes before tapping “Next” (Fig. 66) Select any additions you have tested whilst on site and add op- tional notes to give more detail, then tap “Next” (Fig. 65). Figure 65 Figure 66 Testifire XTR2...
  • Page 38 Test Job. If required, have the client sign off the job with their signature and details before tapping “Close Test Job” (Fig. 67). Figure 67 NOTE: Test details cannot be edited after the job is closed. Ensure all testing is complete with appropriate notes before closing a Test Job. Testifire XTR2...
  • Page 39: Sharing A Test Report

    Once a Test Job is closed it will be listed on the “My Test Jobs” To view a summary, tap the desired job from the My Test Jobs dashboard on the home screen (Fig. 68) dashboard or use the Search function (Fig. 69) Figure 68 Figure 69 Testifire XTR2...
  • Page 40 To share a PDF test report, tap the share icon in the top right and enter the recipients email address (Fig. 70) Figure 70 Testifire XTR2...
  • Page 41: App Settings Menu

    9.8.8 Help The DT Connect app includes access to a range of help and support videos so you can make the most of Testifire XTR2. To access the content, tap the settings icon in the top right hand corner from the home screen and select the “Help” option.
  • Page 42: Give Feedback

    This menu allows you to view the latest Terms & Conditions for DT Connect 9.8.11 Privacy Policy This menu allows you to view the latest Privacy Policy from Detectortesters 9.8.12 Deactivate Account Select this option to deactivate your account. This action is irreversible Testifire XTR2...
  • Page 43: Consumables And Accessories

    Consumables TES3-3PACK-001 Testifire XTR2 Smoke Cartridges x3 TES3-6PACK-001 Testifire XTR2 Smoke Cartridges x6 TESTIFIRE-GEN-1PK-001 Testifire XTR2 Smoke Generator x1 TESTIFIRE-BP-001 Testifire XTR2 Lithium Ion Battery Pack x1 Accessories TESTIFIRE-ADAP-001 Testifire XTR2 ASD Adaptor TESTIFIRE-FA-001 Testifire XTR2 Heat Deflector Spares TESTIFIRE-CHAK-001...
  • Page 44: Troubleshooting

    Check the fan moves freely, if not remove the smoke car- Remove the battery and check the charge indicator. If empty, tridge and generator from within Testifire XTR2. Fan faults recharge the battery. (Fig. 73). may occur to due debris getting inside the unit. Carefully use an air duster and apply to the fan or rotate the fan gen- tly.
  • Page 45: Device Error Codes

    11.1 Device Error Codes In the event of a system fault, Testifire XTR2 will display an error code on the LCD display. Every error code is unique and represents a different fault. Error Description Required Action Code Unit deactivated at first power on due to no connec-...
  • Page 46: Support & Technical

    SUPPORT & TECHNICAL 12.1 Maintenance The Testifire XTR2 unit contains no user serviceable parts. Do not disassemble. In the case of a build-up of dust or dirt on the surface of the product, wipe with a slightly damp lint-free cloth. The area around the smoke/heat duct and within the cup should be cleaned periodically to remove any dirt or fluid.
  • Page 47: Technical Information

    40°C = 3 hours Power consumption: Dependent on mode of use: Smoke testing: <0.5A rms Heat testing: 4-6A rms N.B. Power consumption refers only to the duration of the actual test and may vary considerably due to internal control algorithms. -------------- Testifire XTR2...
  • Page 48: Support Contact

    For help and support, please use contact your local service centre with your product serial number and any error code to hand. United Kingdom Americas No Climb Products Ltd. SDi, LLC Welham Green, AL9 7JE 3535 Route 66, Building 6 Neptune, NJ 07753 Tel: +44 (0) 1707 282760 Tel: 732-751-9266 Email: detectortesters-connect@detectortesters.com Email: service@sdifire.com Web: https://detectortesters.com/troubleshooting Web: https://sdifire.com/support/ Testifire XTR2...
  • Page 49 As our policy is one of continuous improvement, details of products described within this publication are subject to change without notice. All in- formation provided here is believed to be correct at the time of going to press. Every effort has been made to ensure the accuracy of information which is provided in good faith but nothing contained herein is intended to incorporate any representation or warranty, either express or implied or to form the basis of any legal relations between the parties hereto, additional to or in lieu of such as may be applicable to a contract of sale or purchase.