5 Technical Data

Table 2: Technical Data
Dimensions
Height 7 U Systems
Height 8 U System
Width
Depth (20836-716/-815)
Depth (20836-719)
Weight
(20836-716)
(20836-815)
(20836-719)
Power supply
Input voltage
Mains frequency
Power consumption (20836-716/-719)
Power consumption (20836-815)
Cooling
3 x 24 VDC Fans (20836-716/-719)
3 x 24 VDC Fans (20836-815)
Ambient Temperature
Operating
Storage
Humidity
permissable Humidity
EMC, the system meets the
requirements for:
Emitted Interference
Interference Resistance
Safety
Test voltage according to EN 60950
Shock and Vibration:
Electromagnetic Shielding
Shielding attenuation
www.schroff.biz
310.5 mm (7 U)
355 mm (8 U)
483 mm (19")
355 mm
475 mm
17 Kg
18 kg
20 kg
100 VAC to 240 VAC
50 / 60 / 400 Hz
up to 444 W
up to 744 W
Each 170 m³/h (100 cfm)
Each 237 m³/h (140 cfm)
0 °C to +40 °C
-40 °C to +85 °C
30 % to 80 %, non condensing
EN 55022
EN 55024
Input - Output:
Input- PE:
Output - PE:
Output - Output:
EN 60068-2-6 and EN 60068-2-27
typ. 40 dB at 1 GHz if shielded front
panels are used.
20
R1.0, September 22, 2006
Technical Data
4,3 kVDC
2,2 kVDC
0,7 kVDC
0,7 kVDC

Advertisement