Important Notes; Electricity Supply - IDEAL IMAX XTRA EL 320 User Manual

Advertisement

IMAX XTRA EL
320, 395, 470, 545, 620
Natural Gas only
Destination Countries: GB, IE
Introduction
The IMAX XTRA EL is a floor mounted, super efficient
condensing boiler featuring full sequence automatic spark ignition
and fan assisted combustion.
Due to the very high efficiency, condensate is produced from the
flue gases and this is drained to a suitable disposal point through
the condense trap at the rear of the boiler. A condensate 'plume'
will also often be visible at the flue terminal.
Safety
Current Gas Safety (Installation & Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler
must be installed and maintained by a Gas Safe Registered
Engineer or in IE a competent person, in accordance with the
above regulations.
The appliance should be serviced at least once a year by a Gas
Safe Registered Engineer or in IE a competent person.
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

Electricity Supply

The appliance must be earthed.
Supply 230 V - 50 Hz.
The fusing should be 7A.
This appliance is intended to be connected to the supply via a
double-pole switch, having a 3mm contact separation in both
poles, serving only the boiler and system controls.
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the
Commissioning Report. You can check your installer by calling Gas Safe Register direct on 0800 4085500.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
2

Important Notes

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
Do not store objects around or on the boiler, and keep access
clear at all times.
Do not obstruct ventilation ducts, grilles or openings in the
boiler room, room space or compartment that the appliance is
installed in, or the passage of combustion and ventilation to
the boiler.
Do not turn off the boiler if it is to be left unattended in frosty
weather.
If it is known or suspected that a fault exists on the boiler then
it MUST NOT BE USED until the fault has been corrected by a
Gas Safe Registered Engineer or in IE a competent person.
Flammable materials must not be placed in close proximity to
the appliance. Materials giving off flammable vapours must not
be stored in the same room as the appliance.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
In cases of repeated or continuous shutdown a Gas Safe
Registered Engineer or in IE a competent person should be called
to investigate and rectify the condition causing this and carry out
an operational test after each intervention on the device. Only the
manufacturer's original parts should be used for replacement.
Minimum Clearances
Front 700mm
LHS 150mm
To light the boiler
(Refer to Frame 1)
1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.
2. Set the boiler to standby.
3. Switch on the electricity supply to the boiler and check that all
external controls, e.g. programmer, room thermostat, etc are
on. Allow the boiler to carry out a self check.
4. Set the boiler to winter.
The boiler will commence the ignition sequence, supplying heat to
the system when required.
Rear 150mm
RHS 700mm
IMAX XTRA EL - User's