Certified Vents And Dimensions; Certified Vent Installation - Norcold 9162 Installation Requirements

900 & 9100 series
Hide thumbs Also See for 9162:
Table of Contents

Advertisement

The air passage from the intake vent to the refrigerator coils and from the refrigerator coils through the exhaust
vent must be unobstructed .
The vents for this refrigerator have been certified by A.G.A. and CGA and must be installed as directed in this
manual without modification. Any deviation or substitution:
1. Can result in carbon monoxide levels in the living space of the vehicle.
2. Will void the agencies' certifications.
3. Will void the refrigerator warranty.
4. Will effect refrigerator performance.
Table 1 - Certified Vents and Their Dimensions
Note: Combination of lower intake vent and exhaust vent makes up Norcold Vent kit no. 3.
Part No.
Type
617778
Plastic
Square
616010
Corner
Radius
616009
Corner
Radius
615998
Corner
Exhaust
615791
Vent

Certified Vent Installation

Requirements
Certified Vent Kit No. 3 installed with-
out modification.
Intake (lower) vent installed flush with
or below the surface on which the
refrigerator is mounted
Exhaust (upper) vent centered di-
rectly over the condenser of the refrig-
erator's cooling unit
Unobstructed air flow at rear
Cut - Out Dimensions - inches(cm)
Exhaust Vent
Length
Width
13 3/4 (34.93) 21 1/2 (54.61)
- -
- -
- -
- -
- -
- -
- -
- -
24
5 1/4
(60.96)
(13.34)
Figure 2
5
Lower Intake Vent
Height
Width
13 3/4
21 3/4
(34.93)
(55.25)
13 3/4
21 7/8
(34.93)
(55.56)
13 3/4
21 7/8
(34.93)
(55.56)
- -
- -
Approved
Models
Radius
- -
All Models
- -
All Models
3 1/4
All Models
(8.26)
3 1/4
All Models
(8.26)
- -
All Models