  • Page 1 AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT USER’S MANUAL MODELS: O1CMI-09/O1CMO-09 O1CMI-12/O1CMO-12 O1CMI-18/O1CMO-18 O1CMI-24/O1CMO-24 ENGLISH...
  • Page 2 Table of Contents Owner’s Manual Safety Precautions ............04 Unit Specifications and Features ......06 SAFETY FIRST Manual Operation (Without Remote) ....11...
  • Page 3 Care and Maintenance .............12 Troubleshooting ..............14 European Disposal Guidelines ........18...
  • Page 4 Safety Precautions Read Safety Precautions Before Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. This symbol indicates that ignoring instructions may cause death or serious injury.
  • Page 5 ELECTRICAL WARNINGS Only use the specified power cord. If the power cord is damaged, it must be replaced by the • manufacturer or certified service agent. Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty •...
  • Page 6 Unit Specifications and Features Unit Parts Front Panel Power Cable (Some Units) Remote Control Remote Control Holder Louver (Some Units) Display window(A) Display window(C) Display window(B) fresh defrost run timer fresh defrost run timer fresh defrost run timer fresh “ ”...
  • Page 7 Achieving Optimal Performance Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally. Inverter Split Type FOR OUTDOOR UNITS COOL mode...
  • Page 8 For a detailed explanation of each function, Air Filter Reminders (some units) • refer to the Remote Control Manual. Air Filter Cleaning Reminder After 240 hours of use, the “run” & “timer” indicator lamps on the indoor Other Features unit will flash simultaneously and the display window on the indoor unit will Auto-Restart •...
  • Page 9 Setting Angle of Air Flow • Setting vertical angle of air flow While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°.
  • Page 10 Sleep Operation • The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. Press the SLEEP button when you are ready to go to sleep.
  • Page 11 Manual Operation (Without Remote) How to operate your unit without CAUTION the remote control The manual button is intended for testing In the event that your remote control fails to purposes and emergency operation only. Please work, your unit can be operated manually with do not use this function unless the remote is the MANUAL CONTROL button located on lost and it is absolutely necessary.
  • Page 12 Care and Maintenance Rinse the filter with fresh water, then shake Cleaning Your Indoor Unit off excess water. BEFORE CLEANING OR Dry it in a cool, dry place, and refrain from exposing it to direct sunlight. MAINTENANCE When dry, re-clip the air freshening filter to ALWAYS TURN OFF YOUR AIR CONDITIONER the larger filter, then slide it back into the SYSTEM AND DISCONNECT ITS POWER SUPPLY...
  • Page 13 Maintenance – CAUTION Long Periods of Non-Use Before changing the filter or cleaning, • If you plan not to use your air conditioner for an turn off the unit and disconnect its power extended period of time, do the following: supply.
  • Page 14 Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
  • Page 15 Issue Possible Causes A rushing air sound may occur when the louver resets its position. The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
  • Page 16 Troubleshooting When troubles occur, please check the following points before contacting a repair company. Problem Possible Causes Solution Temperature setting may be higher than ambient Lower the temperature setting room temperature The heat exchanger on the indoor or outdoor unit is Clean the affected heat exchanger dirty Remove the filter and clean it...
  • Page 17 Problem Possible Causes Solution Wait for the power to be Power failure restored The power is turned off Turn on the power The fuse is burned out Replace the fuse The unit is not working Remote control batteries are Replace batteries dead The Unit’s 3-minute protection Wait three minutes after...
  • Page 18 European Disposal Guidelines This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this product as household waste or unsorted municipal waste. When disposing of this appliance, you have the following options: •...
  • Page 19 Activate your warranty..Connect to the following link http://www.inventoraiconditioner.com /warranty-inventor simple steps! Select the product type (airconditioner or appliance) for which the warranty will be activated Choose the warranty that corresponds to your product purchase Fill in the required information...
  • Page 20 AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT Scan here to download the latest version of this manual. Σαρώστε εδώ για να κατεβάσετε την τελευταία έκδοση του εγχειριδίου.