Multi Dosage - Specification - Electrolux Millennium 2G Service Manual

Table of Contents

Advertisement

3.13.
Multi Dosage – Specification
 PERFORMANCE 
    The dosage of the rinse‐aid has to be independent of the filling status of the container, as long as the refill indication isn't reached. 
After indicating the refill minimum for another 2 dosage cycles the nominal volume has to be guaranteed. 
 Dosage procedure – Multiple dosage 
    The first activation impulse opens the detergent lid, no rinse aid should be dosed into the tub.   
    With each further activation impulse a dosage volume of 1,5 ml has to be dosed into the tub.  
    The allowed dosage time for 4 dosage cycles is max. 7 minutes. 
    The nominal dosage volume with 4 dosage cycles is 6 ml. 
    The maximum number of dosage cycles is 6. 
    The maximum dosage volume with 6 dosage cycles is 9 ml. 
 Rinse aid volume 
    The rinse aid container must have an available volume of 120 ml +‐3%. All dead volumes in the container have to be minimized. The 
design has to avoid air chambers in the container, which might influence the available volume or the exactness of the dosage. 
The control LED goes on by  +/‐ 40 ml  rest of rins aid into the  container. 
 
 
 
 
 
Technical Support – A.R.
18/43
599 80 15-03 Rev. 01
 