5.16 Dispenser
The new dispenser includes the following features:
•
Low voltage driving - 5VDC => Safety
improvement
•
Multiple dosage => Performance/Quality
improvement
•
Sliding lid => Performance/Quality improvement
5.17 Multi Dosage - Specification
•
PERFORMANCE
The dosage of the rinse-aid has to be independent of
the filling status of the container, as long as the refill
indication is not reached. After indicating the refill
minimum for another 2 dosage cycles, the nominal
volume has to be guaranteed.
Dosage Procedure – Multiple Dosage
The first activation impulse opens the detergent lid; no
rinse aid should be dosed into the tub.
With each further activation impulse a dosage volume
of 1.5 ml has to be dosed into the tub.
During Main Wash Phase – Detergent Lid Opening:
STEP
ACTION
Activation of
1
coil
TIME
PURPOSE
Opening the
0.3 S
detergent lid to
release detergent
During Hot Rinse Phase - Rinse Aid Delivery:
STEP
ACTION
1
Dosage check –
Activation of
2
coil
3
Pause
Repeat from
4
Step 2
28
TIME
PURPOSE
Check if rinse aid is
should be delivered
If 0 -> no delivery
the rinse aid
delivery process
should be stopped.
Delivery of dose
5 S
of rinse aid - 1,5 ml
nominal
Refill of dosage
10 S
chamber
Number of dosages
according to set
–
level