Technical Specifications
Heat Output Range
Heat Output: BTU/hr (kW/hr)
Diesel Fuel Consumption: U.S Gal./hr (L/hr)
Electric Power Consumption: Amps (Watts)
Voltage Operating Range: Volts DC
Operating Modes
Dimensions: LxWxH, Inches (mm)
Weight: lbs (kg)
Kit Contents
22
1
17
13
11
2
15
10
4
9
12 Volt DC
24 Volt DC
12 Volt DC
24 Volt DC
21
20
18
16
14
12
5
7
8
6
Page 4 of 19
Minimum
3071 (0.9)
0.03 (0.11)
0.67 (8)
0.33 (8)
10.5 - 16 with Low and High Voltage Protection
21 - 32 with Low and High Voltage Protection
Automatic Regulation - Adjustable 41°F to 95°F (5°C to 35°C)
Constant Heat Output Selection - Adjustable Min. to Max.
Air Circulation / Ventilation - No Heat, Fan Only
14.61 x 5.51 x 5.91 (371 x 140 x 150)
9.92 (4.5)
1. Main Heater Unit
2. Main Wire Harness
3. Control Switch / Timer
4. Fuel Pump
5. Fuel Pick-up Tube
19
6. Fuel Line
7. Fuel Line Connector Hose Clip
8. Fuel Line Connector
9. Fuel Pump Mounting Bracket
+
-
10. Anti-Vibration Mount
11. Air Intake Pipe
12. Exhaust Pipe
13. Air Intake Pipe Clamp
14. Exhaust Pipe Clamp
15. Air Intake Pipe Mounting Clamp
16. Exhaust Pipe Mounting Clamp
17. Grill
3
18. Outlet Cover
19. Ambient Temperature Sensor
(Optional)
20. Air Ducting Clamp
21. Air Ducting
22. Air Ducting Outlets
Maximum
13649 (4.0)
0.13 (0.51)
2.83 (40)
1.42 (40)