Valley USA, LLC, or one of its affiliates or subsidiaries. All other intellectual property rights are owned by GVBB Holdings SARL, Grass Valley USA, LLC, or one of its affiliates or subsidiaries. All third party intellectual property rights (including logos or icons) remain the property of their respective owners.
Use anti-static procedures, equipment and surfaces during servicing. The presence of this symbol in or on Grass Valley equipment means that it has been tested and certified as complying with applicable Underwriters Laboratory (UL) regulations and recommendations for USA.
Page 5
Notices Warnings A warning indicates a possible hazard to personnel, which may cause injury or death. Observe the following general warnings when using or working on this equipment: • Any instructions in this manual that require opening the equipment cover or enclosure are for use by qualified service personnel only.
• Avoid extreme highlights as these can cause various kinds of optical reflections. • Be careful when connecting and disconnecting fiber cables. • Do not connect Grass Valley camera systems with other manufacturer’s camera system parts. • Make connections swiftly and firmly to avoid false error messages.
Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company. All specifications are subject to change without notice.
XCU Universe XF XCU / HD-4K/XF IP Maintenance Manual Laser Safety - Fiber Output SFP and QSFP Modules Warning LASER SAFETY The average optical output power does not exceed 0 dBm (1mW) under normal operating conditions. Unused optical outputs should be covered to prevent direct exposure to the laser beam.
Notices Safety and EMC Standards This equipment complies with the following standards: Safety Standards IEC62368-1:2018 Audio/video, information and communication technology equipment: part 1 EN 62368-1:2018 EU national deviations. EMC Standards This unit conforms to the relevant Union harmonization legislation and the requirements of the following directive/standards: RED 2014/53/EU EMC testing;...
Page 10
XCU Elite/Worldcam Triax Maintenance Manual This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Page 12
Maintenance Manual EMC performance of cables and connectors Grass Valley products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
Page 14
0031 126 00200 - XCU UNIVERSE XF LEMO HYBRID FIBER List of Field Replacable Units (FRUs): Part Number Description Quantity 4-000000001-00 FRU KIT FOR 300V POWER SUPPLY UNIT 400-00000-01 DISPLAY OLED 80591 1.54" 128x64dots 3922 407 63321 LOCKING HANDLE 3922 407 62633...
Page 15
92: To U2 for XCU Universe XF 92: To U7 for XCU HD 4K XF IP...
Page 16
3922 407 63071 - 19 INCH BS CRADLE List of Field Replacable Units (FRUs): Part Number Description 3922 407 63233 CRADLE MECHANICS 3922 406 56581 PCBA CONNECTOR BOARD...