SERVICE PARTS INFORMATION 8
Thermistor
Check Point : Check Thermistor resistance value
Remove connector and check Thermistor resistance value.
Temperature
[°C]
Thermistor A
- 20
- 10
- 5
0
5
10
15
20
25
30
40
50
60
70
80
90
100
110
120
Discharge temp. TH
Applicable
Thermistors
Resistance Value [ k ]
Thermistor B
---
---
---
27.8
---
21.0
168.6
16.1
129.8
12.4
100.9
9.6
79.1
7.6
62.6
6.0
49.8
4.8
40.0
3.8
26.3
2.5
17.8
1.7
12.3
1.2
8.7
---
6.3
---
4.6
---
3.4
---
2.6
---
2.0
---
Heat exchanger. TH
Heat exchangr(Mid).TH
Thermistor C
105.4
58.2
44.0
33.6
25.9
20.2
15.8
12.5
10.0
8.0
5.3
3.6
---
---
---
---
---
---
---
Outdoor temp. TH