Technical Reference; Application Limits; Motor Data; Specific Motor Data - Xylem Flygt 2400 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Technical Reference

Technical Reference

Application limits

Data
Media (liquid)
temperature
pH of the pumped media
(liquid)
Media (liquid) density
Depth of immersion
Other

Motor data

Feature
Motor type
Frequency
Supply
Starting method
Maximum starts per
hour
Code compliance
Rated output variation
Voltage variation without
overheating
Voltage imbalance
tolerance
Stator insulation class

Specific motor data

3-phase, 50 Hz
Motor type:
• 2,955 rpm
• Rated output 90 kW (121 hp)
Voltage (V)
380
42
Description
Maximum temperature 40°C (104°F)
6–13
3
Maximum density: 1100 kg/m
75 m (250 ft.)
For specific weight, current, voltage, power rating, and speed of the pump, see the data
plate on the pump. For starting current, see
For other applications, contact the nearest Xylem representative for information.
Description
Squirrel-cage induction motor
50 or 60 Hz
MSHA version: 60 Hz
3-phase
Direct on-line
30 evenly spaced starts per hour
IEC 60034-1
±10%
±10%, provided that it does not run continuously at full load
2%
H (180°C [360°F])
Rated current (A)
155
Flygt 2400 Installation, Operation, and Maintenance Manual
(9.2 lb. per US gal.)
Motor data
(page 42).
Starting current (A)
1,170

Advertisement

Table of Contents
loading

Table of Contents