Download Print this page

Troubleshooting - Sealey IR18 Instructions

Infrared paraffin/diesel heater

Advertisement

7. TroUBleSHooTiNG

Problem
Heater fires but shuts down after a short
period
Heater will not operate or motor runs for short
time
fan does not operate when heater is plugged
in and power switch is in the "on" position
Heater does not turn on and lamp is not lit
declaration of Conformity
iNFrAred PArAFFiN/dieSel
HeATer
model: ir18
2006/42/Ec Machinery Directive
2006/95/Ec Low Voltage Directive
2004/108/Ec EMc Directive
93/68/EEc cE Marking Directive
2002/95/Ec roHs Directive
2002/96/Ec WEEE Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
imPorTANT: no liability is accepted for incorrect use of product.
WArrANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFormATioN: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Possible Cause
1. Dirty fuel filter
2. nozzle Dirty
3. Photocell Dirty
4. Photocell not installed properly
5. Photocell defective
6. Improper electrical connection between
Printed circuit board and Photocell
1. No paraffin/diesel in fuel tank
2. corroded spark plug or incorrect gap
3. Dirty fuel filter
4. Dirty nozzle
5. Moisture in fuel tank
6. Improper electrical connection
7. transformer wire not connected to spark
plug
8. Defective transformer
1. Broken electrical connection between
Printed circuit board and motor
1. temperature limit sensor has overheated
2. no electrical power
3. fuse blown
4. Improper electrical connection between
temperature limit sensor and Printed
circuit board
We, the sole importer into the uK, declare that the product listed
below is in conformity with the following standards and directives.
the construction files for this product is held by the manufacturer and may
be inspected, by a national authority, upon request to Jack sealey Ltd.
signed by Mark sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Sole UK distributor
Sealey Group,
Bury st. Edmunds, suffolk.
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
1. clean/replace fuel filter
(see Maintenance)
2. clean/replace nozzle
(see Maintenance)
3. clean/replace Photocell
(see Maintenance)
4. Adjust Photocell position
5. replace Photocell
6. check wiring connections fig.8
1. Fill tank with fresh paraffin/diesel
2. clean/replace spark plug
(see Maintenance)
3. Clean/replace fuel filter
(see Maintenance)
4. clean/replace nozzle
(see Maintenance)
5. Rinse out fuel tank with clean paraffin (See
Maintenance)
6. Inspect all electrical connections
(see Wiring Diagram in Maintenance)
7. re-attach transformer wire to spark plug
8. replace transformer
1. Inspect all electrical connections
(see Wiring Diagram in Maintenance)
1. Push power switch to "off" and allow
heater to cool for 5 minutes.
Push power switch back to "on"
2. check power cord to ensure proper
connection. test power supply
3. check/replace fuse
4. Inspect all electrical connections
(see Wiring Diagram in Maintenance)
01284 757500
Web
01284 703534
email
Solution
1st May 2008
www.sealey.co.uk
sales@sealey.co.uk