6.

mAiNTeNANCe

WARNING! MAINTENANCE MusT ONLY BE uNdERTAkEN BY A quALIfIEd PERsON. WE sTRONGLY RECOMMENd THAT
ALL sERVICING Is dONE BY YOuR LOCAL sERVICE AGENT.
 WARNING! unplug unit from mains power supply before opening or servicing heater.
see section 1 regarding electrical safety and maintenance.
Use only genuine Sealey replacement parts. The use of alternate or third party components can
cause unsafe operating conditions and will void the warranty.
We suggest following a maintenance schedule as follows:
6.1.
FUel TANK
flush every 200 hours of operation or as needed. Do not use water to flush the tank. use fresh
paraffin only.
6.2
FilTerS
the fuel filter and oil filter should be cleaned at least twice per heating season by rinsing it in
clean paraffin. contaminated fuel could make this necessary more frequently. (see fig.3).
6.3
FAN BlAdeS
 WARNING! Never service heater whilst hot or connected to an electrical source.
the fan blades should be cleaned at least once per heating season, depending on conditions.
remove all accumulated dust and dirt with a damp cloth, taking care not to bend any of the fan
blades. Be sure fan blades are dry before re-starting the heater. (fig.4).
6.4
NoZZleS
nozzles should be cleaned or replaced at least once per heating season. contaminated fuel
could make this necessary more frequently.
to clean nozzle, blow compressed air through nozzle front. It may be necessary to soak nozzle
in clean paraffin to help loosen any particles (fig.5).
6.5
SPArK PlUG (Fig.6)
clean and re-gap every 600hrs of operation, or replace as needed.
After removing the spark Plug, clean the terminals with a wire brush. re-gap the terminals to
0.140" (3.5mm).
6.6
PHoToCell
the Photocell should be cleaned at least once per heating season or more depending on
conditions.
use a cotton swab dipped in water or alcohol to clan the lens of the Photocell. note the
Photocell position as fig.7.
6.7
loNG Term STorAGe
6.7.1
unscrew the fuel cap.
6.7.2
Using a syphon suitable for paraffin or diesel to
remove the contents of the fuel tank.
6.7.3
Using a small amount of paraffin, rinse and swirl
the paraffin inside the fuel tank. Empty tank fully.
Never mix water with the paraffin as it will cause
the tank to rust.
never store old fuel in the tank over summer.
using old fuel can damage your heater.
store heater in a safe, dry well ventilated area
away from children.
Be sure that the storage area is free of dust and
corrosive vapours. re-pack the heater in the
original shipping material.
Keep the manual in an easily accessible place.
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Fig.7
Fig.6
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Fig.3
Fig.5

CONTROL PCB

Fig.4
Fig.8
Ir18
Issue no: 1 - 01/05/08

Advertisement

loading