Temperature key:
1. Press the temperature button to adjust it – the light in the middle of the button will be
highlighted. The temperature is displayed using three digits – the first two digits show the
temperature and the last bit shows '°C'.
2. The default temperature is 25°C – change this by pressing the button. It will automatically
confirm after five seconds of no operation or confirm by pressing the temperature button
(temperature range: 15-35°C).
3. When on, hold the temperature button for five seconds – this will change the mode from
Celsius to Fahrenheit. When in Fahrenheit, hold the button for five seconds to switch back to
Celsius.
4. When in Fahrenheit, the default temperature is 77°F – the range is between 59-95°F.
5. The Celsius and Fahrenheit modes have a memory function. If there is a power outage, the
appliance will return to its previous settings when turned back on.
Increase/decrease buttons ▲/▼:
1. When there is not a mode, timer or temperature setting, the two corresponding lights will
be dim. There will be no response when pressing these buttons.
2. When setting a mode, timer or temperature, the two buttons will be active and the indicator
lights will be highlighted.
3. Press the temperature button to set the temperature.
Anti-tip function:
1. When the appliance is tilted, the digital tube flashes and displays 'Eo' – all functions will
turn off.
2. When the appliance is placed back to its upright position, the heater will resume to its
normal working function.
Anti-frost function:
1. When in standby, the mid-range heating will automatically turn on when the probe
temperature is lower than 5°C (41°F). When the probe temperature is higher than 7°C (45° F),
the heating will stop and return to standby.
2. When the frost protection is turned on, the LED will flash every two seconds – the digital
tube will show the current temperature (in degrees Celsius or Fahrenheit).
Note:
1. When on, if there is no operation after three minutes, the appliance will return to standby.
Press any button to return to its normal working state.
2. If there is a sensor short circuit, the letters 'EH' will flash. If there is a sensor open circuit,
the letter 'EL' will flash. If this happens, switch off the power and restart the appliance.