AGAGC9NPS01B Gas Conversion Kit, Natural to Propane: Installation Instructions
!
D'EQUIPEMENT D'OPERATION
Toute erreur de câblage peut être une source de danger et de panne.
Lors des opérations d'entretien des commandes, étiqueter tous les fils
avant de les déconnecter.
NOTE: Use a back-up wrench on the gas valve to prevent the valve
from rotating on the manifold or damaging the mounting to the burner
box.
1. Disconnect the gas pipe from gas valve and remove pipe from the
furnace casing (see
Fig.
1)
2. Disconnect the connector harness from gas valve Disconnect wires
from Hot Surface Igniter (HSI) and Flame Sensor.
3. Support the manifold and remove the four (4) screws that secure the
manifold assembly to the burner box and set aside.
4. Note the location of the green/yellow wire ground wire for
re-assembly later (see
Fig.
5. Remove wires from both rollout switches (see
6. Slide one-piece burner assembly out of slots on sides of burner box
(see
Fig.
3)
7. Remove the flame sensor from the burner assembly.
8. Remove the orifices from the manifold and discard.
Orifice
Manifold
Connect Green/Yellow
ground wire here
Gas Valve
Gas valve is parallel to manifold
C L
within + or - 3˚
Gas valve must be installed on
manifold with minimum engagement of
6 threads. Cross threading is not
acceptable.
Fig. 2 – Manifold Assembly
SINGLE-STAGE GAS VALVE
THIS APPLIANCE HAS BEEN CONVERTED TO USE PROPANE GAS FOR FUEL. REFER TO KIT INSTRUCTIONS FOR CONVERSION
PROCEDURES. USE PARTS SUPPLIED BY MANUFACTURER AND INSTALLED BY QUALIFIED PERSONNEL.
SEE EXISTING RATING PLATE FOR APPLIANCE MODEL NO. AND INPUT RATING.
NOTE: Furnace gas input rate on rating plate is for installations up to 2000 ft. (610m) above sea level. In U.S.A. the input rating for altitudes above 2000 ft. (610m) must
be derated by 2% for each 1000 ft. (305m) above sea level. In Canada the input rating must be derated by 5% for altitudes o f 2000 ft. (610m) to 4500 ft. (1372m) above sea level.
KIT NO.:
AGAGC9NPS01B
APPLIANCE
MODELS
59S(P/C/E), 91(2/5)S,
92(2/5/6)S, PG9(2/5)S,
PG9(2/5)ES, (F/G)9MXE,
F9MES, (N/R)9MS, (N/R)95ES,
(N/R)92ES, WF(A/H/S), (N/R)96VS
* For Canadian Installations from 2000 to 4500 ft. (610m to 1373m) use U.S.A. column 2001 to 3000 ft. (611m to 914m).
∆ THIS KIT IS FOR 40K THROUGH 140K INPUT MODELS ONLY
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
ATTENTION
2)
Fig.
3)
Indicated surfaces
to be 90 ˚+ or -2˚
CONVERSION KIT RATING PLATE
(SUPERSEDES: KGBNP50011SP, KGANP51012SP, KGCNP5201VSP,
NAHD00901LP, NAHB01001LP, AGAGC9NPS01A)
ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A. *
2001 *
0
to 2000
to 3000
1.25mm 1.25mm 1.25mm 1.25mm 1.25mm 1.25mm 1.25mm
Orifice
No.
11.0
11.0
BURNER SUPT. ASSY
BURNER ASSY
ORIFICE SELECTION/DERATE
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
DO NOT re-drill burner orifices. Improper drilling may result in burrs,
out-of-round holes, etc. Obtain new orifices if orifice size must be
changed (see
Fig.
Refer to conversion kit rating plate 346161-201 to determine main
burner orifice size (see
Furnace gas input rate on furnace rating plate is for installations at
altitudes up to 2000 ft. (610 M).
In the U.S.A.; the input rating for altitudes above 2000 ft. (610 M) must
be reduced by 2 percent for each 1000 ft. (305 M) above sea level.
In Canada, the input rating must be derated by 5 percent for altitudes of
2000 ft. to 4500 ft. (610 M to 1372 M) above sea level.
The Conversion Kit Rating Plate accounts for high altitude derate.
A11407
FUEL USED: PROPANE GAS
INLET PRESSURE (min - max): 12.0 - 13.6 in. wc
3001
4001
5001
6001
to 8000
to 4000
to 5000
to 6000
to 7000
Manifold Pressure
11.0
11.0
11.0
11.0
3
IGNITER
FLAME SENSOR
(BELOW BURNER)
Fig. 3 – Burner Assembly
CAUTION
!
4)
BURNER
ORIFICE
Fig. 4 – Burner Orifice
Fig.
5)
7001
8001
9001
to 9000
to 10000
1.25mm 1.25mm
11.0
11.0
11.0
346161-201 REV.A