Adjusting The Electronic Speed Control - Traxxas Slash 4X4 VXL Owner's Manual

Hide thumbs Also See for Slash 4X4 VXL:
Table of Contents

Advertisement

ADJUSTING THE ELECTRONIC SPEED CONTROL

VXL-3s Battery Settings (Low-Voltage Detection Setting)
The Velineon VXL-3s electronic speed control is equipped with built-in Low-Voltage
VXL-3s Specifications
Detection. The Low-Voltage Detection circuitry constantly monitors the battery
Input voltage:
voltage. When the battery voltage begins to reach the minimum recommended
4.8-11.1V (4 to 9 cells
discharge voltage threshold for LiPo battery packs, the VXL-3s will limit the power
NiMH or 2S to 3S LiPo)
output to 50% throttle. When the battery voltage attempts to fall below the
Supported Motors:
minimum threshold, the VXL-3s will shut down all motor output. The LED on the
Brushless
speed control will slowly blink red, indicating a low-voltage shutdown. The VXL-3s
Motor limit:
will stay in this mode until a fully charged battery is connected.
None
When you turn your model on, the VXL-3s speed control's status LED will glow green,
Continuous current:
indicating that Low-Voltage Detection is activated to prevent over-discharging of
200A
LiPo batteries. LiPo batteries are intended only for the most advanced users that
Peak current :
are educated on the risks associated with LiPo battery use.
320A
BEC voltage:
6.0V DC
Transistor type:
MOSFET
To verify the Low-Voltage Detection setting:
Battery connector:
1. Turn on the transmitter (with the throttle at neutral).
Traxxas High-Current
2. Connect a fully charged battery pack to the VXL-3s.
Connector
3. Press and release the EZ-Set button to turn the VXL-3s on. If the LED is solid red,
Motor connectors:
then the Low-Voltage Detection is DISABLED (not safe to use LiPo batteries). If
TRX 3.5mm bullet
the LED is solid green, then Low-Voltage Detection is ACTIVATED.
connectors
To activate Low-Voltage Detection (LiPo setting):
Motor/Battery Wiring:
1. Make sure the LED on the VXL-3s is on and red.
12-gauge Maxx
®
Cable
2. Press and hold the EZ-Set button for ten seconds. The
Thermal Protection:
LED will turn off and then light green. Also, a "rising"
2-stage thermal shutdown
musical tone will be emitted from the motor.
3. Low-Voltage Detection is now ACTIVATED.
To disable Low-Voltage Detection (NiMH setting):
1. Make sure the LED on the VXL-3s is on and green.
2. Press and hold the EZ-Set button for ten seconds. The
LED will turn off and then light red. Also, a "falling"
musical tone will be emitted from the motor.
3. Low-Voltage Detection is now DISABLED.
Transmitter Adjustments for the VXL-3s ESC
Before attempting to program your VXL-3s ESC, it is important to make sure that
your transmitter is properly adjusted (set back to the factory defaults). Otherwise,
you may not get the best performance from your speed control.
The transmitter should be adjusted as follows:
If the transmitter settings have been adjusted, reset them to the factory defaults.
1. Turn the transmitter off.
2. Hold both MENU and SET.
18 • SLASH 4x4
3. Turn the transmitter on.
WARNING: FIRE HAZARD!
Do not use LiPo batteries in this vehicle with Low-Voltage
Detection disabled.
4. Release MENU and SET. The transmitter LED will blink red.
5. Press SET to clear settings. The LED will turn solid green and the transmitter is
restored to default.
VXL-3s Setup Programming (Calibrating your ESC and transmitter)
Read through all of the programming steps before you begin. If
you get lost during programming or receive unexpected results,
simply unplug the battery, wait a few seconds, plug the battery
back in, and start over.
1. Connect a fully charged battery pack to the VXL-3s.
2. Turn on the transmitter (with the throttle at neutral).
3. Press and hold the EZ-Set button (A). The LED will first
turn green and then red. Release the EZ-Set button.
4. When the LED blinks RED ONCE, pull the throttle trigger
to the full throttle position and hold it there (B).
5. When the LED blinks RED TWICE, push the throttle
trigger to the full reverse and hold it there (C).
6. When the LED blinks GREEN ONCE, programming is complete.
The LED will then shine green or red (depending on Low-Voltage
Detection setting), indicating the VXL-3s is on and at neutral (D).
VXL-3s Operation
To operate the speed control and test programming, place the vehicle on a stable
block or stand so that all of the drive wheels are off the ground. Disconnect motor
wires "A" and "C" (see page 12), this will ensure the motor does not drive the wheels
during testing. Do not test programming without disconnecting the motor wires.
Note that in steps 1-7 below, Low-Voltage Detection is ACTIVATED (factory default)
and the LED shines green. If Low-Voltage Detection is DISABLED, the LED will shine
red instead of green in steps 1-7 below. Never use LiPo batteries while Low-Voltage
Detection is disabled.
1. With the transmitter on, press and release the EZ-Set button. The LED will shine
green. This turns the VXL-3s on.
2. Apply forward throttle. The LED will turn off until full throttle power is reached.
At full throttle, the LED will illuminate green.
3. Move the trigger forward to apply the brakes. Note that braking control is fully
proportional. The LED will turn off until full braking power is reached. At full
brakes, the LED will illuminate green.
4. Return the throttle trigger to neutral. The LED will shine green.
5. Move the throttle trigger forward again to engage reverse (Profile #1).
The LED will turn off. Once full reverse power is reached, the LED
will illuminate green.
6. To stop, return the throttle trigger to neutral. Note that there is a programmed
delay when changing from reverse to forward. This prevents damage to the
transmission on high-traction surfaces.
7. To turn the VXL-3s off, press the EZ-Set button until the LED turns
off (.5 seconds).
A
Green then Red
B
Once Red
C
Twice Red
D
Once Green

Advertisement

Table of Contents
loading

This manual is also suitable for:

68286-4

Table of Contents