Advertisement
Classic 3 is built to be safe, simple and straightforward. If after reading this guide, you have any questions or your SteriPEN doesn't operate as described in this manual, please contact us. We love hearing from you! We are here to troubleshoot and make sure you have a working device. Call 888-826-6234 (204-374-4506) or email support@steripen.com.
Also, be sure to visit us online and register your Classic 3 for all the latest news and special deals: www.steripen.com/register.
P.S. Don't forget to recycle the packaging!
www.steripen.com
facebook.com/steripen
@steripen
Specifications
Treatment size: ½ or 1 liter
Treatment time: 48 or 90 seconds
Lamp life: 8,000 activations
Number of liter treatments per set of batteries: (numbers are approximate)
lithium - 150
alkaline - 50
rechargeable - 100
Minimum bottle opening: 22mm
Weight: 83g
Weight with batteries: Lithium: 141g; Alkaline: 178g; Rechargeable: 191g
Length with lamp cover: 186mm
Maximum diameter: 43mm
Remove battery cap by rotating counterclockwise so that cap arrow points to open lock icon .
Install AA batteries with polarities as shown in battery compartment. For best performance, replace all batteries at the same time.
Replace battery cap by aligning cap with open lock icon. Then, rotate cap clockwise until arrow points to closed lock icon .
Classic 3 runs on disposable alkaline batteries, lithium batteries, or rechargeable nickel metal hydride (NiMH) AA batteries with a 2300mAh capacity.
For best results, always use quality, name brand batteries, like Energizer® or Sanyo Eneloop®.
While Classic 3's battery compartment is designed to be highly water-resistant, it is not waterproof. Avoid submerging Classic 3's battery end in water. Classic 3's battery performance may be adversely affected by cold weather. In temperatures below 32ºF/0ºC carry the unit close to your body or warm up batteries before use. If batteries are too cold, Classic 3's LED indicator may give low battery signal. Warm up batteries and treat again.
Make sure to wipe dry after each use.
When not in use, Classic 3 should be kept in a safe place that is clean and dry. It should not be exposed to temperatures above 120°F/49°C or below -4°F/-20°C. Also, when storing for long periods of time, remove batteries to keep them from inadvertently draining.
To clean Classic 3, wash with a soft cloth and a mild soap solution. Rinse soap from device and dry with a clean, soft cloth.
If Classic 3's bulb is cracked, chipped or damaged, don't use it. Return it to the store or contact SteriPEN for repair. Email us at support@steripen.com or call 888-826-6234 (207-374-4506). Do not try to fix it yourself.
The Classic 3's three LED indicator lights let you know the status of your SteriPEN and the water purification process. Green blinking LED(s) indicates succesfull water treatment. The red LED indicates unsuccessful water treatement, low battery level, battery replacement needed, or UV lamp replacement needed.
(One liter = two green LEDs, half liter = one green LED.)
![]() | Successful water treatment | SUCCESSFUL |
![]() | Successful water treatment, batteries low | |
![]() | Successful water treatment, UV lamp good for less than 100 uses | |
![]() | Not submerged in water in time | UNSUCCESSFUL |
![]() | Replace or recharge batteries | |
![]() | Water not detected | |
![]() | Replace UV lamp, UV lamp damaged |
If LED indicators show normal signals, but the lamp does not illuminate, do not consume. Contact SteriPEN support.
Classic 3 is intended for use, and is most effective in clear water but can also be used to treat turbid, murky or cloudy water in an emergency. By doubling treatment time (treating the volume of water twice), Classic 3 can treat water that might be described as: "much closer to clear than opaque," "obviously not clear," "obviously cloudy," "objects viewed through the water are visible but slightly blurry," or "as cloudy as weak lemonade." For best UV purification results, if the water is less clear, filter it first with the SteriPEN® PreFilter, FitsAll Filter® or other method.
Classic 3 is not designed to treat volumes of water larger than one liter. If more than one liter needs treatment, the water should be divided into ½ liter and one liter volumes and treated separately.
When operating properly, the UV lamp will emit visible light as well as UV light. If the lamp is not emitting visible light, it is not functioning properly and should not be used until it has been repaired.
Agitation of water by stirring Classic 3 or rocking the container is necessary, as it promotes uniform purification. Classic 3 is not intended to purify water above the surface of the water in the container, such as droplets on the sides of the container.
Classic 3 is not intended to purify surfaces of a drinking container, like the mouth of the bottle. Be certain that you always wipe the bottle's mouth dry with a clean, dry cloth before drinking.
Classic 3 may be used in glass, plastic, ceramic, or metal containers, as they all absorb or reflect UV light, thereby shielding the user from UV exposure.
Classic 3 is not intended for use by children.
Classic 3 is a high voltage device. Removal or tampering with the electronic circuit board or lamp assembly may cause injury, or damage. Do not open, expose, modify, or touch internal circuitry; doing so can lead to high voltage shock. As with other fluorescent-type lamps, Classic 3 contains a small amount of mercury. At the end of its life, please dispose of Classic 3 properly. For specific instructions contact your local waste disposal organization.
Classic 3 is not intended to treat liquids other than water. Do not use in water with ice. Do not use in water above 120°F/49°C.
As with any other water treatment system, always have a backup method.
While carefully controlled microbiological testing of all SteriPEN products has been conducted, use of all SteriPEN products in the field may produce results that vary from our laboratory test data.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not attempt to bypass water sensor; it is an important safety feature.
Do not handle SteriPEN with wet hands; do not touch water sensor pins with wet fingers.
This device emits UV light, direct exposure may be harmful.
Do not use UV lamp as a light source.
Do not use near skin, eyes, or insert into bodily orifices.
Pre-Filter removes large particles, such as leaves, twigs, sand and other debris for improved UV purification effectiveness. The Pre-Filter is not intended to be a purification method.
To store Pre-Filter, insert filter cartridge with air vent pointing down and rotate clockwise to lock in place. Fits most wide-mouthed bottles, like Nalgene®.
Specifications
Nominal filter size: 40 microns
Weight: 45g
47.5 x 67.9mm diameter
For best results, wet filter cartridge before filling to improve water flow. Rub the mesh with a clean cloth until it becomes thoroughly saturated.
Remove Pre-Filter before drinking.
Air vent is not intended for use as a mouthpiece.
SteriPEN does not treat water droplets on the Pre-Filter's body or threads. Be sure to wipe dry any wet surfaces before drinking.
Get in touch! We are always happy to hear from you: visit www.steripen.com, email support@steripen.com or call 1-888-826-6234 (207-374-4506).
Why am I getting a blinking red LED and no light from the UV lamp?
Check your batteries. SteriPEN® products are high-powered devices that require good, strong batteries to run the UV lamp.
It looks like the tip of Classic 3's lamp is melting — is this normal?
What you are seeing is a small bead of silicone used as a shock absorber to protect the lamp.
What happens when I've used Classic 3 8,000 times?
Classic 3's LED indicator will flash red three times then green once to indicate that its bulb is exhausted. Contact us to have it replaced. Classic 3's bulb is shining a purple, rather than blue light — is it still working? Yes. The visible light indicates that the bulb is working regardless of its color.
Yes. Classic 3 and all SteriPEN® products are allowed in carry-on bags, as well as checked luggage. Does altitude affect Classic 3's ability to purify water?
No. SteriPEN® products have been tested and used on Mount Everest for years. Cold temperatures, however, can affect battery performance, so keep warm them before use.
Can I use Classic 3 to treat more than 1 liter at a time?
No, we do not recommend it. Classic 3's effectiveness is ONLY tested and certified for volumes up to 1 liter.
What about parasites like worms and their eggs? Does Classic 3 treat for them?
Due to animal testing restrictions, Classic 3's effectiveness against such parasites has not been certified.
No. UV light will not effectively destroy microbes in beverages other than water.
Hydro-Photon, Inc.
PO Box 675
262 Ellsworth Road
Blue Hill, Maine 04614 USA
Toll Free USA: 1-888-SteriPEN
(+1) 207-374-5800
info@steripen.com
www.steripen.com
© 2014 Hydro-Photon, Inc.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download SteriPEN Classic 3 - Water Filtration System User Guide
Advertisement
Need help?
Do you have a question about the Classic 3 and is the answer not in the manual?
Questions and answers