Amana PTH073J35A Installation Instructions & Owner's Manual page 4

Package terminal air conditioner/heat pump
Table of Contents

Advertisement

• Energy Management System Features
Temperature Setback - This option can save energy dol-
lars for unrented or unoccupied rooms by automatically
setting back the operational temperatures. This mode of
operation is selected through the configuration routine
(see Configuration Settings section). NOTE: Temperature
setback does not work with a wired remote thermostat.
Door Switch and Motion Sensor Low Voltage Terminals (IN1,
IN2, COM) - The door switch and motion sensor operate as
a unit, the terminals allow for wired connection of a door
sensor to the control board. The motion sensor interprets
any door movement as a signal of occupancy. If the switch
between IN* and COM is closed, the door control will in-
terpret the room door as closed. If the switch between
IN* and COM terminals is opened (or closed if unit is con-
figured for normally open) the control will interpret the
action as a signal of occupancy. If thirty minutes pass with-
out any door activity, Energy Management Temperature
setback activates.
Serial Port Interfaces - A serial port, located on the con-
trol board, provides easy access for two-way communica-
tions to the control board from an optional RF antennae
can be attached for wireless communications.
TRANSPORTATION DAMAGE
All units are securely packed in shipping containers tested
according to International Safe Transit Association specifica-
tions. The carton must be checked upon arrival for external
damage. If damage is found, a written request for inspection by
the carrier's agent must be made immediately.
In the event of damage, the consignee must:
1.
Make notation on delivery receipt of any visible damage to
shipment or container.
2.
Notify carrier promptly and request an inspection.
3.
In case of concealed damage, carrier should be notified as
soon as possible—preferably within 5 days.
4.
File the claim with the following supporting documents
within the 6 month statute of limitations.
a. Original Bill of Lading, certified copy, or indemnity
bond.
b. Original paid freight bill or indemnity in lieu thereof.
c. Original invoice or certified copy thereof, showing
trade and other discounts or reductions.
d. Copy of the inspection report issued by carrier's
representative at the time damage is reported to the
carrier.
The carrier is responsible for making prompt inspection of
damage and for a thorough investigation of each claim. The
distributor or manufacturer will not accept claims from dealers
for transportation damage.
UNIT ACCESSORIES
This unit is designed for through-the-wall installation in new or
existing buildings. To complete the installation of this PTAC, an
insulated wall sleeve and an outdoor grille (either the stamped
aluminum grille, the architectural grille or polymer grille) are
required.
The chassis and the cabinet front are shipped in one carton.
Optional accessories to complete a particular installation are
the following:
OPTIONAL ACCESSORIES
Power Switch Kit
Wall Sleeve Kit
Key Lock Kit
Drain Kit
Filter Kit
Subbase Kit
Hard Wire Kit
Main Duct Kit
Power Door Kit
Leveling Legs Kit
Hydronic Heat Kit
Stamped Grille Kit
Curtain Guard Kit
Polymer Grille Kit
Extension Duct Kit
NOTE: Consult sales literature for the appropriate voltage and
amperage selections, if applicable. For additional details and
illustrations of the accessories, refer to the Architect's and
Engineer's Manual.
4
Wire Harness Kit
Circuit Breaker Kit
Architectural Grille Kit
Remote Escutcheon Kit
External Transformer Kit
Water or Steam Valve Kit
Condensate Disposal Pump Kit
Remote Temperature Sensor Kit
Wireless RF Antenna
Wireless RF Thermostat
Wireless Motion Sensor
Wireless Door Switch
Extra Deep Sleeves
Wall Thermostat Kit
Fuse Holder Kit