    MT-510AC Thank you for purchasing our Welding Transformer MT-510AC. ・ This operation manual explains its method of operation and precautions for use. ・ Before using, read this operation manual carefully; after reading, save it in a proper place where you can easily access.
  • Page 3: Special Precautions

    MT-510AC 1. Special Precautions (1) Safety Precautions CAUTION ! Before using, read "Safety Precautions" carefully to understand the correct Denotes operations and practices that method of use. may result in personal injury or damage to the equipment if not correctly followed.
  • Page 4 MT-510AC W ARNING Do not put your hands between the electrodes. When welding, keep your fingers and hands away from the electrodes. Do not touch any welded part or electrodes during welding and just after welding finished. The welded part of a workpiece, electrodes and arm are very hot.
  • Page 5 MT-510AC CAUTIO N Apply the specified source voltage. Application of a voltage out of the specified range can cause fire and electric shock. Do not splash water on the Equipment. Water splashed over the electric parts, can cause electric shock and short circuits.
  • Page 6 MT-510AC (2) Precautions for Handling  Install the Equipment on a firm and level surface. If it is used inclined or on its side, it may have a malfunction.  Do not install this Equipment in the following places: ▪ Where there is considerably damp (humidity is higher than 90%).
  • Page 7: Features

    MT-510AC 2. Features The MT-510AC is the AC spot welding transformer suitable for welding small precision components such as thin metal sheets. 3. Specifications Rated Primary Voltage 200 V AC +/-10% 50/60 Hz Rated Secondary Voltage OFF, 1.2 V, 1.8 V, 2.5 V, 3.5 V (without Load)
  • Page 8: Description Of Operation

    Current Running Time Duty Factor = x 100 (%) Running Interval Also, if the capacity of the control is rather small, the control may break, so be sure to use the proper welding control which fits to MT-510AC.
  • Page 9: Wiring

    MT-510AC 5. Wiring 6. Other Information (1) Be careful to handle with the transformer because 200 V AC is applied on the primary side. (2) Do not put any voltage to the secondary, or it may break the control. (3) Do not change “POWER” switch during supplying current.
  • Page 10: Outline Drawing

    MT-510AC 7. Outline Drawing (Dimensions in mm) (15) 3 . 5V 2 . 5V 2-φ9 1 . 8V 1 . 2V O F F P 0W E R SPEC I F ICA T ION IN PU T VO L T AG E : 2 0 0V±1 0% A C 5 0 / 6 0 H z...