Figure 5-1 - Dew Point Chart °F; Figure 5-2 - Dew Point Chart °C - Gardner Denver AUTO SENTRY EAU99G Operating And Service Manual

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
20
30
110
100
90
80
70
60
50
40
30
20
-10
-5
0
These charts are easily used by reading the ambient temperature along the bottom axis of the chart and
then reading the appropriate pressure curve to determine the corresponding dew-point temperature on
the left axis of the chart. The compressor discharge temperature must be maintained at a minimum of
10° F above this dew-point temperature to prevent condensation accumulation in the lubricant reservoir.
These charts assume 100% relative humidity.
Dew-Point Temperature vs. Ambient Temperature
(100% Relative Humidity)
40
50
60
Ambient Temp. F
Figure 5-1 – DEW POINT CHART °F
Dew-Point Temperature vs. Ambient Temperature
(100% Relative Humidity)
5
10
15
20
Ambient Temp. C
Figure 5-2 – DEW POINT CHART °C
13-10-614
70
80
90
25
30
35
Page 39
100 psig
125 psig
150 psig
175 psig
100
110
120
6.9 bar
8.6 bar
10.4 bar
12.1 bar
40
45
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auto sentry eau99hAuto sentry eau99m

Table of Contents