Download Print this page

ADTRAN jobAid PR30 Manual page 2

10g pon small form-factor pluggable olt transceiver

Advertisement

Environmental
Operational Case Temperature Range: 0°C to +70°C
Storage Temperature Range: –40°C to +85°C
Relative Humidity: up to 95%, noncondensing
S
R
AFETY AND
EGULATORY
E
NGLISH
!
WARNING
Read all warnings and cautions before installing or servicing this
equipment.
C
CAUTION
This product is a Class 1 Laser module that complies with FDA 21
CFR 1040.10 and 1040.11 and IEC 60825-1. This product is NRTL
Listed and CB Certified to all applicable American and European
safety standards. For continued compliance with the above
standards, install only ADTRAN-approved Class 1 Laser
Modules in ADTRAN products. For a list of ADTRAN-approved
SFPs and XFPs, see http:/www.adtran.com/SFP. ADTRAN
cannot certify system integrity with other laser modules.
!
CAUTION
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
This product and host system are designed and intended for
installation as part of either a Common Bonding Network
(CBN) or Isolated Bonding Network (IBN).
This product does not have an internal DC connection
between battery return and frame ground. This product can be
installed in a DC-I (isolated) or DC-C (common) configuration.
The chassis frame ground terminal must be connected to an
earth ground to ensure that the exposed metal (i.e., front
panels, SFP/XFP modules) on the product is properly
grounded by way of the backplane connector.
NOTE
The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR-
1089-CORE.
This product is designed to be deployed in GR-3108-CORE
environmental Class 1.
This product is NRTL Listed to the applicable UL Standards.
The product is designed to meet the applicable requirements
of Telcordia GR-63-CORE and GR-1089-CORE.
This product has also been evaluated to international safety
standards EN 60950-1, AS/NZS 60950.1, and IEC 60950-1. This
product meets the requirements for CE marking under the
EMC Directive and Low Voltage Directive. Standards used to
demonstrate Compliance are EN 300 386 and EN 60950.
2
C
OMPLIANCE
The product is intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the NEC applies
(for example, Customer Premises).
This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
This product is designed to meet the following environmental
classes:
ETSI EN 300 019-2-1 "Classification of environmental condi-
tions; Storage Class" 1.2
ETSI EN 300 019-2-2 "Classification of environmental condi-
tions, Transportation", Class 2.3
ETSI EN 300 019-2-3 "Classification of environmental condi-
tions, Stationary use at weather protected locations", Class
3.1E
This product is designed to function without degradation
during exposure to all test severities per Class 3.3 of ETSI EN
300 019-1-3.
This product meets EU RoHS Directive 2011/65/EU and/or
applicable exemptions. Refer to
information on RoHS/WEEE.
www.adtran.com
for further
61442548F1C-22B