Installation & Use Manual
Soft Sides
INSTALLER
Elkay Fountains are among the easiest to install Fountains on the market today. To assure you install these
models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL,
AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future
reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s) contains
the Freeze Resistant Package(s) LKFRB1 that are installed on an interior heated wall. The interior space must
maintain a minimium temperature of 50° F (10° C). Refer to the Freeze Resistant Package for the rough-in
dimensions for installation.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
ECDFPW314FP
Freeze Resistant Fountain
®
IMPORTANT
Page 1
WWW.RESTROOMDIRECT.COM
704 • 937• 2673
129 Oakpark Dr., Unit A, Mooresville, NC 28115
98011C (Rev. L - 02/18)

Advertisement

loading

Summary of Contents for Elkay Soft Sides ECDFPW314FP

  • Page 1 ® INSTALLER Elkay Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
  • Page 2 ECDFPW314FP 98011C (Rev. L - 02/18) Page 2 WWW.RESTROOMDIRECT.COM 704 • 937• 2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115...
  • Page 3 ECDFPW314FP 98011C (Rev. L - 02/18) Page 3 WWW.RESTROOMDIRECT.COM 704 • 937• 2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115...
  • Page 4 ECDFPW314FP CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play FIG. 3 FIG. 4 See Fig. 7 FIG. 5 See Fig. 3 FIG. 6 FIG. 7 98011C (Rev. L - 02/18) Page 4 WWW.RESTROOMDIRECT.COM 704 • 937• 2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115...
  • Page 5 ECDFPW314FP The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted.
  • Page 6 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com 98011C (Rev. L - 02/18) Page 6 WWW.RESTROOMDIRECT.COM...