Functions/features explanation

Repair instruction

If you have replaced the PCBA for whatever reason, you always need to check/adjust per coffee button the
recipe type (SENSEO brew, Intensity select enabled/disabled or Jug brew) and volume setting. The PCBA
ordered from service has standard the "General version" volume setting pre-installed and Intensity select
function is enabled for the 1-cup button. (may be subject of change)

Volume measurement procedure:

Below steps, describe how to measure the (water) volume.
You can apply this procedure for checking the SENSEO brew volume per function. (country volume or
Intensity select short/normal)
1. Make sure the boiler is filled with water.
2. Switch appliance ON and wait until the unit is ready to brew.
3. Place a 1-cup pod holder without a Coffee POD. (only adjusting with plain water)
4. Place a cup on the drip tray cover and push the one-cup button.
5. When the appliance has finished, you are able to perform the volume adjustment.
6. Empty the cup, podholder and push again for one cup setting, measure the volume output with a
graduated beaker.
In the table "general coffee specifications", you can find the requirements for the minimum / maximum water
volume output cc/ml values for each function.
How to change the volume, is described in chapter "Programming the recipe function / change the volume"
In the latest PCBA introduced Augustus 2018 onwards it is possible to program any recipe setting for each
button. This means by modifying the recipe mode or function you can easily program the 1-cup button as
Jug button or enable/disable the intensity select version and vice versa. Therefore, it is very important that
every PCBA will be checked on the correct recipe mode for the SENSEO type it is applicable for.
In below table the recipe/brew function per button is described for each type number. The volume
specification is based on country type, see table "general coffee specifications".
Buttons
1-cup button
2-cup button
MUG button
(Nordic)
Jug button
SENSEO brew
Drip filter brew
(coffee spec)
100/122 ml
200/244 ml
200 ml
Intensity select
enabled 60/120 ml
Type numbers
HD6592, HD6594,
HD6596, HD6597
HD6592, HD6596
All types
Intensity select
disabled
Type numbers
HD6591, HD6593
HD6591, HD6593
HD6593, HD6594,
none
n.a.
HD6597
n.a.