EWM Phoenix 355 Progress puls LP MM TKM Operating Instructions Manual page 82

Hide thumbs Also See for Phoenix 355 Progress puls LP MM TKM:
Table of Contents

Advertisement

Design and function
Special parameters (advanced settings)
"Single or dual operation" (P10) setting
If the system is fitted with two wire feeds, no further accessory components may be operated on
the 7-pole connection socket (digital)!
This relates to digital remote controls, robot interfaces, documentation interfaces, welding
torches with digital control lead connection, etc.
No second wire feed may be connected in single operation (P10 = 0)!
• Remove connections to the second wire feed
In dual operation (P10 = 1 or 2), both wire feed units must be connected and configured differently
on the controls for this operating mode!
• Configure one wire feed unit as the master (P10 = 1)
• Configure the other wire feed unit as a slave (P10 = 2)
Wire feed units with key switches (optional, - See 5.17 Protecting welding parameters from
unauthorised access chapter) must be configured as masters (P10 = 1).
The wire feed configured as the master is active after the welding machine is switched on. There
are no other functional differences between the wire feeds.
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
JOB list switching (P12)
Value Designation
0
Task-oriented
JOB list
1
Actual JOB list
2
Actual JOB list,
JOB changeover active
82
Explanation
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
090-005502-EW501
25.11.2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Phoenix 355 Progress puls LP MM TKM and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents