en Troubleshooting
Fault
Remnants of food on table-
ware.
50
Cause
Tableware was placed too
close together.
Basket is overfilled.
Spray arm rotation is
blocked.
Spray arm nozzles are
blocked.
Filters are soiled.
Filters are inserted incor-
rectly and/or not engaged.
Washing programme selec-
ted too weak.
Tableware has been pre-
cleaned too intensely. The
sensors chose a weaker pro-
gramme. Stubborn soiling
cannot be entirely removed.
Tall narrow receptacles in
corner areas are not rinsed
adequately.
Top baskets on right and left
are not set to same height.
troubleshooting
Arrange tableware with sufficient
1.
space in between.
The spray jets must reach the sur-
faces of the tableware.
Avoid points of contact.
2.
Arrange tableware with sufficient
1.
space in between.
The spray jets must reach the sur-
faces of the tableware.
Avoid points of contact.
2.
Arrange tableware so that it does
▶
not obstruct spray arm rotation.
Clean the Spray arms → Page 44.
▶
Clean the filters.
▶
→ "Cleaning filters", Page 43
Insert the filters properly.
1.
→ "Filter system", Page 43
Engage the filters.
2.
Select a more intensive washing
▶
programme.
Adjust the sensitivity of the sensors.
▶
Only remove large remnants of food
▶
and do not prerinse tableware.
Adjust the sensitivity of the sensors.
▶
Do not position tall narrow recept-
▶
acles at too great an angle or in
corner areas.
Set the top baskets on the left and
▶
right to the same level.
→ "Top basket", Page 23