Unit Type
Cooling RTU with optional
Electric Heat Legacy Series
Model
J = Puron Refrigerant
Voltage
E = 460-3-60
J = 208/230-1-60
P = 208/230-3-60
T = 575-3-60
Cooling Tons
08 - 7.5 ton
09 - 8.5 ton
12 - 10 ton
14 - 12.5 ton
16 - 15 ton
Refrig. System Options
A = Standard One-Stage cooling models
D = Two-Stage cooling models 08-16
K = Two-Stage cooling models with Perfect
Humidity™ (08-16)
Heat Level
(Field-installed electric heaters available)
000 = No Heat
Coil Options For Round Tube/Plate Fin Condenser Coil Models Only
(Outdoor-Indoor-Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu - Louvered Hail Guards
N = Precoat Al/Cu - Al/Cu - Louvered Hail Guards
P = E-coat Al/Cu - E-coat Al/Cu - Louvered Hail Guards
Q = E-coat Al/Cu - E-coat Al/Cu - Louvered Hail Guards
R = Cu/Cu - Al/Cu - Louvered Hail Guards
S = Cu/Cu - Cu/Cu - Louvered Hail Guards
Coil Options For All Aluminum-Novation® Condenser Coil Models Only
(Outdoor-Indoor-Hail Guard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-coat Al/Cu
K = E-coat Al/Al - Al/Cu
L = E-coat Al/Al - E-coat Al/Cu
T = Al/Al - Al/Cu, Louvered Hail Guards
U = Al/Al - Cu/Cu, Louvered Hail Guards
V = Al/Al - E-coat Al/Cu, Louvered Hail Guards
W = E-coat Al/Al - Al/Cu, Louvered Hail Guards
X = E-coat Al/Al - E-coat Al/Cu, Louvered Hail Guards
8
J
E
0
8
A
0
0
Fig. 1 — 558J 08-16 Model Number Nomenclature (Example)
0
A
1 A
0
A
A
Packaging, Controls & Indoor Fan
Motor Speed Options
A = Standard Packaging, electro mech. controls
B = LTL Packaging, electro mech controls that
C = Standard Packaging, electro mech. controls
D = Standard Packaging and 2-Speed Indoor Fan
E = LTL Packaging and 2-speed Indoor Fan Motor
F = LTL Packaging, electro mech. controls that
Factory-Installed Options
Outdoor Air Options
A = None
B = Temp Econo, Baro Relief, Standard Leak (W7212 or
W7220)
H = Enthalpy Econo, Baro Relief, Standard Leak (W7212 or
W7220)
E = Temp Econo, Baro Relief, Standard Leak w/ CO2
(W7212 or W7220)
L = Enthalpy Econo, Baro Relief, Standard Leak w/CO2
W7212 or W7220)
Q = Motorized 2 Position Damper
U = Temp Econo, Baro Relief, Ultra Low Leak, (W7220)
W = Enthalpy Econo, Baro Relief, Ultra Low Leak (W7220)
Indoor Fan Options
0 = Direct Drive ECM (Sizes 04-06 / -P voltage only)
1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option
C = High Static Option with High Effy Motor - Bel
Drive (Size 16 only)
NOTE: On single phase (-J voltage code) models, the following
are not available as a factory installed option:
- Perfect Humidity
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2-Position Damper
- Powered 115 Volt Convenience Outlet
3
that require W7212 EconoMi$er® IV
require W7212 EconoMi$er IV
that require W7220 EconoMi$er X
Motor (VFD) Controller
(VFD) Controller
require W7220 EconoMi$er X