Operation of the AirSmart controller is easy. Simply select a Target Pressure and then press the Run
button to start the compressor, no other settings are required. The Target Pressure comes
preset from the factory at pressure as ordered. The Unload Pressure is preset to 10 psi higher. If a
different pressure setting is desired, the following steps can be used as a guide.
·
Setting the Target Pressure
The Target Pressure setting is used to set the operating point of the compressor. To make any
adjustments in the operation of the compressor, the machine must be stopped and in the Ready
mode. Stop the compressor by pressing the Stop/Reset
should read "READY" on line 3.
0 PSI
10 HRS
READY
NO SERVICE ADVISORY
Next, press the Enter
ADJUSTMENT MENU
OPERATION ADJUSTMENT
(SELECT SUB MENU)
Since the Target Pressure setting is under the Operation Adjustment menu, press Enter
again to access that sub-menu
OPERATION ADJUSTMENT
LANGUAGE-LANGUAGE
ENGLISH (US)
(SELECT PARAMETER)
The Target Pressure is the second item in the Operation Adjustment sub-menu so press the
Down
button to navigate to the Target Pressure setting.
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(SELECT PARAMETER)
To change the Target Pressure, press the Enter
OPERATION ADJUSTMENT
TARGET PRESSURE
100 PSI
(EDIT PARAMETER)
A flashing cursor will appear covering the least significant digit in the Target Pressure value, use
the Plus
and Minus
Quick Start Guide
75°F
AUTOMATIC
button to access the Adjustment Menu tree
buttons to change its value. Use the Right
13-18-609
button. The front panel display
button to edit the value.