Propane forced air heaters

Advertisement

NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Specifications
Rating
Model #
BTU/Hr
MH-40-GFA
42,000
40,000 -
MH-60V-GFA
60,000
95,000 -
MH-125V-GFA
125,000
120,000-
MH-150V-GFA
150,000
Table 1:
Specifications
Unpacking
1. Remove all packing items applied to heater for shipment. Keep
plastic cover caps attached to inlet connector and hose/regula-
tor assembly for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged,
promptly inform dealer where you purchased the heater.
The Propane (LP) gas pressure regulator
CAUTION
and hose assembly supplied with the
heater must be used without alteration.
This is an unvented portable heater. It
CAUTION
uses air (oxygen) from the area which it is
used. Ample combustion and ventilation air must be provid-
ed. See VENTILATION on page 5.
Product Features
- Portable, stable and fully assembled.
- Wind resistant and rain protected.
- Continuous spark ignition or piezo spark ignition.
- 100% safety shut-off system.
- Adjustable input ratings (Except MH-40-GFA).
- Adjustable Height Controller.
PROPANE INFORMATION
The Propane (LP) cylinder must also be
equipped with the following:
- A collar to protect the gas valve.
- A shut-off valve terminating a LP cylinder
valve outlet as specified in the American
National Standard for Compressed Gas
Cylinder Valve Outlets and Inlet Connections.
- A safety relief valve having direct communica-
tions with the vapor space of the LP cylinder.
- An arrangement of vapor withdrawal.
Page 2
Fuel
Consumption
1.9 Lbs/Hr
1.9 to 2.8 Lbs/Hr
4.4 to 5.8 Lbs/Hr
5.5 to 6.9 Lbs/Hr
Specifications subject to change without notice
Figure 1. Product Features
Pinnacle Products International, Inc. Propane Forced Air User's Manual
Electrical
Manifold
Input
Pressure
120V, 60 Hz
11" W.C.
120V, 60 Hz
11" W.C.
120V, 60 Hz
8.3" W.C.
120V, 60 Hz
8" W.C.
DANGER
result causing property damage, personal injury or loss of
life.
- Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
- An LP cylinder not connected for use shall not be stored
in the vicinity of this or any other appliance.
- WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
- DO NOT attempt to light heater
- Extinguish any open flame
- Shut off gas to heater
- If odor continues, contact your local gas supplier or
fire department.
- Do not touch any electric switch, do not use any
phone in your building
- Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions
- If you can not reach your gas supplier, call the fire
department
- Service must be done by a qualified service agency
or the gas supplier.
WARNING
Combustion by-products produced when using this product contain car-
bon monoxide, a chemical known to the state of California to cause can-
cer and birth defects (or other reproductive harm).
Propane
Forced Air Heaters
Weight
Amps
(Lbs)
0.6
11.2
18" x 7" x 13"
0.6
11.2
18" x 7" x 13"
0.8
17.6
25" x 8.6" x 15.5"
0.8
17.6
25" x 8.6" x 15.5"
If the information in this manual is not
followed exactly, a fire or explosion may
The state of California requires the following
warning:
Size
(L x W x H)