DO NOT LET THE SCREEN CHAMBER DROP!! Guide cradle to it's resting
position.
The knives mounted on the rotor, and the bed knives located at the edges of the
cutting chamber, are extremely sharp. Always wear heavy gloves and exercise
care when working in the cutting chamber.

5-2 Closing Screen Chamber

- 22 -
WARNING!
6. Remove the screen(s) and place them upright on their side.
CAUTION!
1. Ensure all tools, screws, and debris is removed from the
inside of the screen chamber.
2. Place the screen back into its original position, ensuring it
is fully seated within the cradle, then CAREFULLY raise
the chamber to its closed position. Tighten the captive
screw.
3. Insert optional airveyor into the two clips located on either
side of the unit walls (see photo).
4. Before leaving the area, make sure all components are
connected properly.
5. Close door on sound enclosure.
Optional Airveyor
should be inserted into
these clips located on
either side of the unit.