3-4 Electrical Service Connections
All equipment must be grounded in compliance with Article 250 of the National
Electric Code. The customer's disconnecting means and branch circuit
protection must also be in compliance with the National Electric Code and all
Local Codes.
3-5 High Amperage Readings
NOTE: Make sure the granulator is not drawing excessive
LOW VOLTAGE LINE
•
•
4
5
Y
HIGH VOLTAGE LINE
AC Motor
- 19 -
Carefully check the diagrams packed with the machine. All
internal wiring has been done at the factory and safety
interlocks have been verified for proper functioning before
shipment. It is only necessary to connect the electrical
power source to the machine at the control enclosure.
WARNING!
amperage.
1. Check appropriate amperage as listed on the motor
nameplate.
2. Measure amperage with ammeter by connecting
ammeter to incoming power feed wires. Make sure
machine is not drawing more than amperage listed on
the nameplate. The amperage will change according to
motor size.
3. If amperage exceeds the amount listed on nameplate,
check the following:
•
Sharpness of knives
•
Quoted feed rate of granulator
HP
FRAME
VOLTS
AMPS
•
230/460
Amperage
6
208
May not meet NEMA
torque on 208V systems
NEMA
NEMA
DESIGN B
NOM. EFF.
CONT
MAX
@
DUTY
AMB
PH3
RPM
BEARINGS DRIVE/OPP
SERIAL
INS
TV
HZ60
TYPE KM
SERVICE
NEMA
TEMP
FACTOR
CODE
RISE
MADE IN USA