Carrier GAPAAXCC1625 Product Data

4 way multipoise induced combustion gas furnace input capacities 45,000 thru 135,000 btuh

Advertisement

58PHA/PHX PERFORMANCE™ BOOST 80
4---WAY MULTIPOISE
INDUCED---COMBUSTION GAS FURNACE
Input Capacities: 45,000 thru 135,000 Btuh
Series 110/120
THE CARRIER PERFORMANCEt BOOST 80

GAS FURNACE

The 58PHA/PHX 4- -way Multipoise Gas Furnaces offer deluxe
features not found in other single- -stage 80% gas furnaces. The
ECM motor and Carrier's control logic combine to provide a
SEER BOOST of up to 1.5 points.* Carrier's QuieTecht noise
reduction system makes the Performancet Boost 80 an incredibly
quiet induced- -draft gas furnace.
The gas furnace control system provides a dehumidification mode,
a motor speed selection for continuous fan operation selectable at
the thermostat, and fault code storage in the event of power
outages. Applications are easy with 4- -way multipoise design,
through- -the- -furnace downflow venting, 13 different venting
options, and a design for easy service access. An inner blower door
is provided for tighter sealing in sensitive applications. The
*as compared to the Air Conditioning Heating and Refrigeration Institute's standard coil ---only rating when paired with selected Carrier evaporator coils.
Product Data
58PHA/PHX furnaces are approved for use with natural or propane
gas, and the 58PHX is approved for use in Low NOx Air Quality
Management Districts.
STANDARD FEATURES
S ECM Blower Motor included
S QuieTecht noise reduction system
S SmartEvapt—Humidity control when using a
Thermidistatt Control
S ComfortFant—adjustable constant fan speed from the
thermostat
S Microprocessor based control center
Enhanced diagnostics with LED and reflective sight glass.
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow
Dehumidification selection for summer- -time cooling
S 4- -way Multipoise furnace, 13 vent applications
S Compact design - - only 33- -1/3 in. (847 mm) tall
S Power Heat SiNt Igniter
S Draft safeguard switch to ensure proper furnace venting
A10251
S Insulated blower compartment
S Inner door for tighter sealing
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1- -In.
Water Gauge with all present air inlets and air outlet sealed.
S HYBRID HEAT Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Residential installations eligible for consumer financing
through the Retail Credit Program
1

Advertisement

Table of Contents
loading

Summary of Contents for Carrier GAPAAXCC1625

  • Page 1: Gas Furnace

    An inner blower door is provided for tighter sealing in sensitive applications. The *as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil ---only rating when paired with selected Carrier evaporator coils.
  • Page 2: Furnace Components

    FURNACE COMPONENTS INDUCER MOTOR VENT ASSEMBLY ELBOW MAIN LIMIT SWITCH (BEHIND GAS VALVE) PRESSURE SWITCH BLOCKED VENT SWITCH FLUE COLLECTOR FLAME SENSOR GAS VALVE GAS MANIFOLD MANUAL RESET LIMIT SWITCHES HOT SURFACE IGNITOR GAS BURNER BLOWER DOOR SAFETY SWITCH FURNACE CONTROL BLOWER AND BOARD...
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE 58PHA Nominal Cooling Size (Airflow at .5 e.s.p.) 400 CFM per 12,000 Btuh) 08 --- 800 CFM 12 --- 1200 CFM 20--- 2000 CFM 58PHA Deluxe 4--- Way Multipoise Series Number 58PHX Low NOx Version Input Rates 045 --- 44,000 Btuh 070 --- 66,000 Btuh 090 --- 88,000 Btuh...
  • Page 4: Specifications

    SPECIFICATIONS UNIT SIZE 045 -- 08 070 -- 16 090 -- 16 110 -- 20 135 -- 20 RATINGS AND PERFORMANCE Input Btuh* 58PHX Upflow; all 58PHA 44,000 66,000 88,000 110,000 132,000 Nonweatherized ICS 58PHX Downflow/Horizontal 42,000 63,000 84,000 105,000 126,000 Output Capacity (Btuh)†...
  • Page 5 CARRIER ACCESSORIES DESCRIPTION PART NO. 045---08 070---16 090---16 110---20 135---20 FILCABXL0016 Media Filter Cabinet FILCABXL0020 FILCABXL0024 FILCCCAR0016 Cartridge Media Filter FILCCCAR0020 FILCCCAR0024 EXPXXUNV0016 EZ Flex Media Filter with End Caps EXPXXUNV0020 EXPXXUNV0024 EXPXXFIL0016 Replacement EZ Flex Filter Media EXPXXFIL0020 EXPXXFIL0024...
  • Page 6: Typical Wiring Schematic

    CARRIER ACCESSORIES ACCESSORIES ELECTRONIC AIR Model EACB CLEANER (EAC) AIR PURIFIER Models GAPAAXCC1625, GAPAAXCC2025 MECHANICAL AIR Models EZXCAB, FILCAB CLEANER HUMIDIFIER Model HUM HEAT RECOVERY Model HRV VENTILATOR ENERGY RECOVERY Model ERV VENTILATOR UV LIGHTS Model UVL For use with 1---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP---NAC, TC ---NAC For use with 1---speed Heat Pump --- deg.
  • Page 7 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,7,8,9 UPFLOW UPFLOW DOWNFLOW A02061 A02058 A02059 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02062 A02060 A02063 Venting Notes 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), NFPA54/ANSI Z223.1.
  • Page 8 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02067 A02066...
  • Page 9 AIR DELIVERY - - CFM (WITH FILTER)* EXTERNAL STATIC PRESSURE (In. W.C.) UNIT SIZE COLOR SPEED Gray 1185 1145 1115 1075 1035 Yellow 045---08 Blue Orange --- --- Gray 1625 1585 1535 1495 1460 1415 1365 1295 1220 1125 Yellow 1405 1360 1320...
  • Page 10 A10269 Always Ask For Use of the AHRI Certified Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
  • Page 11: Guide Specifications

    GUIDE SPECIFICATIONS Casing Casing shall be of .030- -in. (.76 mm) thickness minimum, Gas Furnace pre- -painted steel. 58PHA/PHX Inducer Motor GENERAL Inducer motor shall be soft mounted to reduce vibration System Description transmission. Draft Safeguard Switch Furnish a _________________ fixed capacity gas- -fired furnace for use with natural gas or propane (factory authorized conversion Draft Safeguard Switch (blocked vent safeguard) shall be factory kit required for propane);...
  • Page 12 Catalog No: 58PHA ---08PD Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 08/13 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 58PHA--- 07PD...

This manual is also suitable for:

Gapaaxcc2025

Table of Contents