Hans Grohe AXOR Citterio 39454 1 Series Installation/Warranty
Hans Grohe AXOR Citterio 39454 1 Series Installation/Warranty

Hans Grohe AXOR Citterio 39454 1 Series Installation/Warranty

Hide thumbs Also See for AXOR Citterio 39454 1 Series:

Advertisement

Quick Links

Installation / Warranty
Citterio
39454XX1

Advertisement

Table of Contents
loading

Summary of Contents for Hans Grohe AXOR Citterio 39454 1 Series

  • Page 1 Installation / Warranty Citterio 39454XX1...
  • Page 2: Technical Data

    Axor Citterio four-hole roman tub set 39454XX1 Technical Data Flow rate @ 45 psi 6.0 gpm per side Handshower 2.5 gpm max. Maximum water pressure 145 psi Recommended water pressure: 14.5 - 75 psi Recommended hot water temp.: F - 140 *Some municipalities limit the maximum water temperature from the water heater to 120 below.
  • Page 3: Installation Instructions

    Installation Instructions The water supply must be turned off at the main prior to installation of this kit. • Remove the plastic plaster shields from the valves and the spout tee. Use a phillips head screwdriver to remove the screws from the white plastic handle snap connectors.
  • Page 4 • Remove the brass plug from the end of the high pressure hose. Attach the chrome inner Secu-flex hose. Use the enclosed Hansgrohe Color towelette to clean and lubricate the inner hose. Have a co-worker use the towelette to clean and lubricate the ends of the outer hose.
  • Page 5 • Lower the handshower holder onto the handshower tee, feeding the hose assembly under the tub. The hole on the rear of the handshower holder should go over the positioning pin on the handshower holder tee.Install the handshower holder escutcheon over the handshower holder.
  • Page 6 • Use a phillips head screwdriver to loosen the screw inside the handle assembly 3 complete turns clockwise. • Pull upward on the lever to remove it. Turn it approximately 60 . Reinsert it. Tighten the screw. • Reinstall the handle.
  • Page 7 • Place the spout over the diverter assembly. Insert the diverter knob and tighten. Tighten the set screw, using the enclosed 3 mm allen wrench. • Pull outward on the inner Secu-flex hose. Install a screen washer in the hose end connector. Install the handshower.
  • Page 8: Troubleshooting

    User Instructions • Turn the left handle to obtain hot water, the right handle to obtain cold water. • When the water comes on, it will come through the spout. Pull the diverter lever up to divert the water to the handshower. When the water is turned off, the diverter will automatically reset to the spout position.
  • Page 9: Limited Lifetime Consumer Warranty

    Cleaning Recommendation for Hansgrohe Products Modern faucetry and shower products utilize a combination of materials to comply with the needs of the market with regard to design and functionality. To avoid damage, it is necessary to use some caution when cleaning. Damage caused by improper treatment is not covered under the Hansgrohe warranty.
  • Page 10 THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: Conditions, malfunctions or damage not resulting from defects in material or workmanship. Conditions, malfunctions, or damage resulting from (1) improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration, or (2) the use of abrasive or caustic cleaning agents or “no rinse”...
  • Page 12 Hansgrohe Inc. 1490 Bluegrass Lakes Parkway Alpharetta GA 30004 770 360 9880 website: www.hansgrohe-USA.com...