Setting The Control Board - Kenner KND800 User Manual

Sliding gate opener
Table of Contents

Advertisement

The BLUE wire of the exit wand should be connected to the "15" terminal.
The RED wire of the exit wand should be connected to the "18" terminal.
The GREEN wire of the exit wand should be connected to the "19" terminal.
The sensitivity adjustment board should be wired to the GREEN wire and the YELLOW wire of the wand.
The polarity does not matter.
7. Battery
The "24V+" of the battery should be wired to the BAT+ "11" terminal, "24V-" should be wired to the "-BAT"
"10" terminal. If the battery is being used with solar panel, please connect the batteries, solar panel and solar
controller by referring to the chapter "Connecting batteries, solar panels and solar controller".
8. External Receiver
The BROWN wire of the external receiver should be connected to the "16" terminal.
The BLACK wire of the external receiver should be connected to the "17" terminal.
The RED wire of the external receiver should be connected to the "18" terminal.
9. Wired Keypad (24VDC)
The RED wire of the wired keypad should be connected to the "18" terminal.
The BLACK wire of the wired keypad should be connected to the "17" terminal.
The BLUE wire of the wired keypad should be connected to the "16" terminal.
The PURPLE wire of the wired keypad should be connected to the "17" terminal.
NOTE: If the batteries and solar panel is used as the main power supply, using a photocell, exit wand,
wired keypad or external receiver would quickly exhaust the batteries. Bigger capacity batteries and
solar panels are required if you want to use any one of them.

Setting the control board

WARNING: Ensure the gate opener is Powered Off when you make any adjustment to the gate opener.
Keep away from the path of the gate while setting the gate opener system in case of unexpected gate
movement. Carefully adjust the DIP switches to avoid the risk of machine damage and injury or death.
Always ask the help of professional technician /electrician if you have any questions.
1. DIP Switches
The DIP switches are used to set the running time of the
motor in pedestrian mode, make fine adjustments to the soft stop period of the motor, set auto close time of
the gate opener and set the open/close direction depending on the installed position of the gate opener.
DIP Switch #1–#2: Running time of the motor in Pedestrian Mode
DIP Switch #1: ON – 2 Seconds OFF – 0
DIP Switch #2: ON – 4 Seconds OFF – 0
NOTE: The pedestrian mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled. The pedestrian mode could be activated by pressing button B of the
remote control when the gate is in the fully closed position.