SERVICES POWER SUPPLY TEST.
Power board (12), rectifier bridge W1, negative terminal (-) and diode D2 cathode (+) = +25
Vdc, with switch (21) closed and mains voltage 230 Vac.
♦ Check the wiring between CN3 of power board (12) and transformer (31).
♦ With power source powered check the following voltages at the primary circuit of
transformer (31):
CN3, terminals 8 and 10 = 115 Vac;
CN3, terminals 7 and 9 = 115 Vac;
CN3, terminals 7 and 10 = 0 Vac with mains 230 Vac; 115 Vac with mains 115
Vac.
If incorrect replace relay RL1 on power board (12) or complete power board (12).
If correct, make sure the following voltages are present on the secondary circuits
of the transformer (31):
CN3, terminals 1 and 2 = 190 Vac; terminals 4 and 5 = 18 Vac.
If incorrect, with power source off temporarily disconnect CN3 from power board
(12) and check the resistance between the following terminals of CN3:
CN3, terminals 1 and 2 = approximately 1.7 ohm; terminals 4 and 5 =
approximately 0.7 ohm.
If incorrect replace the power board (12). If correct, replace transformer (31).
CONTROL BOARD (2) POWER SUPPLY TEST.
Control board (2), connector CN2, terminals 14 (–) and 1 (+) = + 5 Vdc, with switch (21)
closed.
♦ Check the wiring between CN2 control board (2) and CN4 power board (12).
♦ With power source off, temporarily disconnect connector CN4 from power board
(12) and turn the power source back on. Make sure that on CN4 of power board
(12), terminals 14(-) and 1(+) = +5 Vdc. If correct, check the wiring between CN2
control board (2) and CN4 power board (12), and replace control board (2) if
necessary. If incorrect replace the power board (12).
♦ Replace the control board (2).
3.302.311
YES
Correct?
NO
YES
Correct?
NO