INSTRUCTION MANUAL FOR PLASMA CUTTER
IMPORTANT:
BEFORE STARTING THE EQUIPMENT,
READ THE CONTENTS OF THIS MANUAL, WHICH MUST
BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR
THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WEL-
DING OPERATIONS.
1 SAFETY PRECAUTIONS
WELDING AND ARC CUTTING CAN BE
HARMFUL TO YOURSELF AND OTHERS.
The user must therefore be educated again-
st the hazards, summarized below, deriving from welding
operations. For more detailed information, order the manual
code 3.300.758
NOISE
This machine does not directly produce noise excee-
ding 80dB. The plasma cutting/welding procedure
may produce noise levels beyond said limit; users
must therefore implement all precautions required by law.
AND MAGNETIC FIELDS - May be dangerous.
· Electric current following through any conduc-
tor causes localized Electric and Magnetic
Fields (EMF). Welding/cutting current creates
EMF fields around cables and power sources.
· The magnetic fields created by high currents
may affect the operation of pacemakers. Wearers of vital
electronic equipment (pacemakers) shall consult their physi-
cian before beginning any arc welding, cutting, gouging or
spot welding operations.
· Exposure to EMF fields in welding/cutting may have other
health effects which are now not known.
· All operators should use the followingprocedures in order to
minimize exposure to EMF fields from the welding/cutting cir-
cuit:
- Route the electrode and work cables together - Secure
them with tape when possible.
- Never coil the electrode/torch lead around your body.
- Do not place your body between the electrode/torch
lead and work cables. If the electrode/torch lead cable is
on your right side, the work cable should also be on your
right side.
- Connect the work cable to the workpiece as close as
possible to the area being welded/cut.
- Do not work next to welding/cutting power source.
EXPLOSIONS
· Do not weld in the vicinity of containers under pres-
sure, or in the presence of explosive dust, gases or
fumes. · All cylinders and pressure regulators used in
welding operations should be handled with care.
ELECTROMAGNETIC COMPATIBILITY
This machine is manufactured in compliance with the
instructions contained in the standard IEC 60974-10 (CL. A),
and must be used solely for professional purposes in an
industrial environment. There may be potential difficul-
ties in ensuring electromagnetic compatibility in non-
industrial environments.
8
DISPOSAL OF ELECTRICAL AND ELECTRONIC
EQUIPMENT
Do not dispose of electrical equipment together
with normal waste!In observance of European
Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with
national law, electrical equipment that has reached the
end of its life must be collected separately and returned
to an environmentally compatible recycling facility. As
the owner of the equipment, you should get information
on approved collection systems from our local represen-
tative. By applying this European Directive you will
improve the environment and human health!
IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL.
1.1 WARNING LABEL
The following numbered text corresponds to the label
numbered boxes.
1
1.1
2
2.1
F
O F
3
3.1
4
4.1
5
5.1
6
G
k
la
g
x
m
b
n
z x
Ghgopglòdfòxlc òkvfàlxcvò l+dòvòùx
g
n
,
h
s x
x
h
n
m
j
Sm,nxcv,mzx.c ierlòdfb-.èeì',c mdlò
g
n
x
a
k
j
m
s k
s u
s k
hsjkklasjlòsòlxc,òz
t g
z x
w
k
h
e
x
s d
n
s k
c
h
jhgfjksdhfjksdklcsmkldc
js
m
jk
c
s d
jk
x
c
1.
Cutting sparks can cause explosion or fire.
1.1 Keep flammable materials away from cutting.
1.2 Cutting sparks can cause fires. Have a fire extingui-
sher nearby, and have a watchperson ready to use it.
1.3 Do not cut on drums or any closed container.
1.2
1.3
2.2
2.3
3.2
3.3
4.2
4.3
7
?
3098464

Advertisement

Table of Contents
loading

Summary of Contents for Cebora Power Plasma 2025/M

  • Page 1 INSTRUCTION MANUAL FOR PLASMA CUTTER IMPORTANT: BEFORE STARTING THE EQUIPMENT, DISPOSAL OF ELECTRICAL AND ELECTRONIC READ THE CONTENTS OF THIS MANUAL, WHICH MUST EQUIPMENT BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR Do not dispose of electrical equipment together THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
  • Page 2: General Description

    The plasma arc can cause injury and burns. 2.1 Turn off power before disassembling torch. 2.2 Do not grip material near cutting path. 2.3 Wear complete body protection. Electric shock from torch or wiring can kill. 3.1 Wear dry insulating gloves. Do not wear wet or damaged gloves.
  • Page 3: Explanation Of Technical Specifications

    This value usually corresponds to the capa- high/low piloting voltage of the IGBT. In this case, swit- city of the fuse (delayed type) to be used as ch off the machine and contact the Cebora S.p.A. tech- a protection for the equipment. nical service.
  • Page 4: Maintenance

    cutting current return wire, and connected to the work- • The nozzle holder must be replaced when the insulating piece at the same point as the return wire using the return part is deteriorated wire clamp or a second grounding clamp placed in the Make sure the diffuser U, the electrode T and the nozzle immediate vicinity.
  • Page 5: Generator Maintenance

    6.1 GENERATOR MAINTENANCE In the case of maintenance inside the machine, make sure that the switch C is in position "O" and that the power cord is disconnected from the mains. Also make sure the power voltage at the ends of the con- densers is close to 0 V.
  • Page 6 QUESTA PARTE È DESTINATA ESCLUSIVAMENTE AL PERSONALE QUALIFICATO. THIS PART IS INTENDED SOLELY FOR QUALIFIED PERSONNEL. DIESER TEIL IST AUSSCHLIEßLICH FÜR DAS FACHPERSONAL BESTIMMT. CETTE PARTIE EST DESTINEE EXCLUSIVEMENT AU PERSONNEL QUALIFIE. ESTA PARTE ESTÁ DESTINADA EXCLUSIVAMENTE AL PERSONAL CUALIFICADO. ESTA PARTE È...
  • Page 7 CODIFICA COLORI WIRING DIAGRAM CODIFICA COLORI WIRING DIAGRAM CABLAGGIO ELETTRICO COLOUR CODE CABLAGGIO ELETTRICO COLOUR CODE NERO BLACK ROSA-NERO PINK-BLACK ROSSO GRIGIO-VIOLA GREY-PURPLE GRIGIO GREY BIANCO-VIOLA WHITE-PURPLE BIANCO WHITE BIANCO-NERO WHITE-BLACK VERDE GREEN GRIGIO-BLU GREY-BLUE VIOLA PURPLE BIANCO-ROSSO WHITE-RED GIALLO YELLOW GRIGIO-ROSSO GREY-RED...
  • Page 8 Art. 270 DESCRIZIONE DESCRIPTION DESCRIZIONE DESCRIPTION 01 FASCIONE HOUSING 23 PIEDE IN GOMMA RUBBER FOOT 02 SUPPORTO MANICO HANDLE SUPPORT 24 FONDO BOTTOM 25 MORSETTIERA TERMINAL BOARD 03 MANICO HANDLE 04 GHIERA RING NUT 26 PRESSACAVO CN GHIERA STRAIN RELIEF WITH NUT 05 SUPPORTO RIDUTTORE REGULATOR SUPPORT 27 PRESSACAVO...
  • Page 9 Art. 270...
  • Page 10 TABELLE DI TAGLIO CUTTING CHARTS Art. 270 - 20 A Porta ugello Ugello Elettrodo Diffusore Nozzle holder Nozzle Electrode Swirl ring Art. 1906 Art. 1291 Art. 1878 Art. 1641 Acciaio dolce Acciaio inossidabile Alluminio Mild steel Stainless steel Aluminium Corrente di Velocità...
  • Page 11 CEBORA S.p.A - Via Andrea Costa, 24 - 40057 Cadriano di Granarolo - Bologna - Italy Tel. +39.051.765.000 - Fax. +39.051.765.222 www.cebora.it - e-mail: cebora@cebora.it...