Heiman HEIEHS1SA Quick Start Manual

Smart smoke sensor

Advertisement

Quick Links

Heiman
Smart Smoke Sensor
SKU: HEIEHS1SA
Quickstart
This is a Alarm Sensor for Europe. To run this device please insert fresh 1 * CR123A batteries. Please make sure the internal battery is fully charged. - Press
the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green led will turn off.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not
in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave
device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of
security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The smart smoke sensor detects smoke, and sends an alarm signals to alertof danger.When the smart smoke sensor detects smoke, it will send an alarm notification
to your gateway through wireless Z-Wave communication protocol.Then the gateway will send the notification to the server, the server interprets the signal and
transfers the signal to users' APP. The smart smoke sensor has high stabilityand sensitivity,which will alert house of fire effectively.

Prepare for Installation / Reset

Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this
by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use
the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
- Long press Net-Button while installing batteries in HS1SA-Z.
- Device Reset Locally notification is Transmitted.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.

Installation

- Flat ceiling mounting
The preferred location to install smoke sensor is in the centre of the ceiling, because smoke, heat and combusible products rise to ceiling and will laterally spread.
Keep at least 30 cm distance from lights or decoration and at least 17cm away from walls and corners.
- Sloping ceiling mounting
If ceiling is sloping, please install the smok sensor at horizontal distance 90 cm away from the ceiling top.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEIEHS1SA and is the answer not in the manual?

Questions and answers

Summary of Contents for Heiman HEIEHS1SA

  • Page 1 Heiman Smart Smoke Sensor SKU: HEIEHS1SA Quickstart This is a Alarm Sensor for Europe. To run this device please insert fresh 1 * CR123A batteries. Please make sure the internal battery is fully charged. - Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
  • Page 2 Installation guide - Anticlockwise rotation the bracket out from the installation base. - Fixed the bracket intoceiling using srews. - Remove the double-sided adhersive and stickalarm into ceiling...
  • Page 3 - Remove the battery insulating strip to make detector on power and clockwise rotating alarm into bracket. Inclusion/Exclusion On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network.
  • Page 4 significantly decreased. This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations.
  • Page 5 Manufacturer Specific V2 Notification V4 Powerlevel Sensor Binary V2 Version V2 Wake Up V2 Zwaveplus Info V2 Explanation of Z-Wave specific terms Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

This manual is also suitable for:

6971348970048

Table of Contents