ETC Installation Guide
PCP Mk2 Replacement Kit
Configure the Processor
Note:
the PCP-Mk2. See
facing
Access the Factory Menu
1. Hold down the [1] key while rebooting the processor until the
Manufacturing Tests menu appears.
• To reboot the processor: Press the reset switch at the bottom
right with a non-sharp, pointed object (e.g. a pen).
2. Release the [1] key.
• You will now have access to the Manufacturing Tests menu.
3. Use [Up] (‡ ) and [Down] (ˆ ) to navigate to the Rack Class Test menu.
4. Press [Enter] (ü) to confirm the selection.
5. Use [Up] (‡ ) and [Down] (ˆ ) to select the appropriate rack type and press enter to commit the
selection.
• ERP - for US ERP racks
• ERPCE - for CE EchoDIN systems
• Sensor IQ - for Sensor IQ Intelligent Breaker Panels
• ERP-FT - for ERP-FT racks
6. Press [Back] ( ) two times to exit the factory menu.

Power Calibration

Note:
the power supply is not correctly calibrated, the unit will display BACK UP POWER ACTIVE
on the screen, or will display incorrect voltage values.
To calibrate a panel, you will need a measurement of the incoming voltage. Voltage measurement
should only be undertaken by trained personnel wearing appropriate protective equipment.
1. Access the Factory Menu. See
2. Use [Up] (‡ ) and [Down] (ˆ ) to navigate to Calibration.
3. Use the numeric key pad to enter the measured voltage, multiplied by 100.
• For example, if your measured voltage was 120.26 V, you would enter 12026.
4. Press [Back] ( ) to exit the Calibration screen.
5. Press [Back] ( ) a second time to boot to the main software.
PCP Mk2 Replacement Kit
After configuring the PCP-Mk2 via the UI, save the configuration file and reboot
Save Configuration on the facing page
page.
Power supply calibration only applies to ERP Mains Feed and Sensor IQ panels. If
Access the Factory Menu above